15

Subject to error and alteration

W&T

 

 

Universal Fiber Optic Interface Converter

Glass fiber optic transmission lines are the solution of choice 
when you need to implement absolutely noise-free serial  
data transmission over long distances and/or in noisy  
environments.

Whereas the attenuation with plastic fiber optics places a limit 
of maximum 100 meters on the attainable cable length, the 
distances achievable with glass fiber optics are significantly 
greater and at a comparable cable cost.

The fiber-optic solution offers another significant advanta-
ge: The data transfer is carried out with minimal delay and  
enables the processing of real-time protocols.

Wiesemann & Theis offers an entire family of various fiber 
optic interfaces that allow you to convert critical I/O ports 
or serial ports into an optical port for connecting glass fiber 
optic cable.

This interface family is described on the following pages 
along with the corresponding technical data and including 
connection examples.

For up-to-date information on new developments, see our 
Internet site at http://www.wut.de or check the e-mail 
short notices at the W&T Interface Club, which you can also  
subscribe to from the W&T Homepage.

Содержание 81215

Страница 1: ...13 Subject to error and alteration W T Universal Fiber Optic Interface Converter Manual Universal FO Interface Converter Model 81215 Release 1 0 W T...

Страница 2: ...rification Please inform us of any error or misunderstanding you come about so we can identify and eliminate it as soon as possible Carry out your work on or with W T products only to the extent that...

Страница 3: ...fiber optic solution offers another significant advanta ge The data transfer is carried out with minimal delay and enables the processing of real time protocols Wiesemann Theis offers an entire famil...

Страница 4: ...ply 17 Galvanic isolation and ESD protection 17 Display elements 18 Serial Port 19 RS232 mode 19 RS422 mode 19 RS485 mode 19 RS422 RS485 4 wire bus master application 19 RS485 4 wire RS485 2 wire appl...

Страница 5: ...SUB D connector Power Supply The supply voltage for the Interfaces is provided through an integrated switching regulator This regulator has a variable input voltage range and allows the Interface to b...

Страница 6: ...the fiber optic converter is configu red as a DB9 plug The pin configuration can be seen in the following table Pin RS232 signal RS422 RS485 signal 1 n c TxD A 2 RxD RxD A 3 TxD DTR A active level 4...

Страница 7: ...TxD in both directions RS422 mode This mode provides one data channel each RxD and TxD in both directions The RS422 sender and receiver chips are always active RS485 mode In all RS485 modes there is a...

Страница 8: ...ain after the end of transmission The RS485 receiving channel is deactivated when the driver is on but is switched on when the driver is in the high impedance state Please see the following table for...

Страница 9: ...310 nm Depending on the attenuation value of the glass fiber optic cable used data transmission over a distance of up to 20 km is possible using the Interface in its standard version A special version...

Страница 10: ...as article number 81900 Housing The W T Fiber Optic Interface is contained in a plastic housing for mounting on standard rails according to DIN EN 50022 35 To configure the RS232 RS422 RS485 Interfac...

Страница 11: ...T plug adapter on request Fiber optic medium Duplex single mode fiber 9 125 m Duplex multi mode fiber 50 125 m or 62 5 125 m Wavelength 1310 nm Output power Single mode fiber min 12dBm max 8dBm Class...

Страница 12: ...5 08mm spacing labeled L and M Galvanically isolation min 1 kV between serial interface and power supply Misc Ambient temperature Storage 40 70 C Operation 0 70 C Permissible relative humidity 0 95 rH...