Example:
min. 10°C / max. 18°C / Hysteresis 2°C
When a limit is exceeded the alarm status is reset when 16°C (18-
2) is reached or when the value falls below 12°C (10+2). If the
temperature rises or falls by more than 2°C in five minutes the
alarm is also triggered.
Relative Humidity/Scalar / Absolute Humidity:
The settings made here have exactly the same function as the
temperature settings.
Delay Time:
The alarm is triggered with a delay of this time (in
minutes) to compensate for short-term limit value violations.
Interval:
Enter here the send interval (in minutes) for sending a
message when there is an active alarm. If you want to send just a
single message, enter an „E“ here.
Timer:
This timer interval is based on the CRON service such
as is used in Linux/Unix systems. Valid characters are:
*
: stands for all valid values in the respective input field (e.g.
all minutes or all hours)
-
: specifies a range of from ... to .. For example, weekday „2-4“
stands for Tuesday to Thursday, whereas entering a „*“ triggers
the timer on all weekdays.
/
: Interval within the entered range , e.g. minute „0-45/2“ starts
the timer in the range between the 0th and 45th minute every
two minutes (0, 2, 4, 6 ,8, 10, ... , 44).
,
: specifies an absolute value. For example minute 0, 15, 30
starts the timer on the hour, quarter-hour and half=hour.
This function requires that the „Timer“ box be checked.
Содержание Web-Thermo-Hygrobarograph 57613
Страница 20: ...20 W T Design and positioning of the graph is configurable 2 2 Config menu...
Страница 31: ...31 W T Subject to errors and changes 3 5 1 Basic Settings 3 5 Configuration of the graphics settings...
Страница 37: ...37 W T Subject to errors and changes...
Страница 42: ...42 W T 3 8 2 Alarm X Here you configure the desired alarm conditions...
Страница 90: ...90 W T 7 6 Declaration of Conformity...