24
3.6 Commissioning the Appliance
3.6.1 Pilot Ignition Check
1. Ignite the pilot light as described in the User Instructions
2. Check that the pilot flame stays alight
3. Extinguish the pilot light
3.6.2 Main Burner Check
1. Ignite the pilot light as described in the User Instructions
2. Turn on the main burner as described in the User Instructions
3. Check that the pilot smoothly cross-lights to the main burner and that the main burner and pilot stay alight
4. Check the operation of the second “effect” burner as described in the User Instructions
5. Extinguish the appliance fully
3.6.3 Pressure Check
The appliance is preset to give the correct heat inputs as listed in the technical details. No further adjustment is
necessary. Always check the inlet pressure and burner pressure.
1. Turn off the gas valve on the appliance
2. Release the screw on the Inlet Pressure test point on the gas valve and connect a manometer
3. Check that the measured pressure is as the prescribed supply pressure
4. Perform the test when the appliance is burning on full (inc. “effect” burner) and with only the pilot alight
5. If the pressure is low, check the gas supply pipes are too a correct sizing
6. If the pressure is too high (more than 5 mbar over) the appliance may be installed, but the gas supply company
should be contacted
7. Release the screw on the Burner Pressure test point on the gas valve and connect a manometer
8. Check that the measured pressure is as detailed in the Technical details
9. The measured value should be /- 10% of the described value. If this is not the case, please contact the
supplier.
Note: After checking the pressures and removing the manometers, the screws in the Pressure
Test points must be closed, and the system must be checked for gas-tightness.
4. Servicing
Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to start
servicing the appliance. No liability can be accepted by Wanders for injury caused by burning or scolding by a hot
appliance.
A suggested procedure for servicing is listed below.
A. Lay out dust sheet on flooring, mask off any special fireplace materials.
B. Remove Side Window Trims
C. Remove Bottom Window Trim
D. Remove Window Assembly
E. Carefully remove the Ceramic components (including Embers) or Gravels
F. Use a Vacuum cleaner to clean the top of the burners and grate
G. Remove Grate
H. Remove all 3 Burner Top assemblies, there are 3 M6 flange bolts holding each in
I. Using a vacuum cleaner, fully clean both Burner Top.
J. With the Burner Tops now removed, the Pilot and the heads of the injectors are clearly visible. Use the
vacuum cleaner and a soft brush to clean the pilot assembly and both Injectors. Never modify or bend the
Thermocouple
K. Replace the burner top assemblies and fix in with the fixings
L. Turn on the gas supply and check for leaks, check the burners and Pilot for good condition and operation
Содержание Lenga 500
Страница 6: ...6 3 3 3 Mantel Clearances 3 3 3 a Combustible Mantel side view...
Страница 7: ...7 Installation Servicing and User Instructions EN 3 3 3 b Combustible Mantel Side Wall top view...
Страница 17: ...17 Installation Servicing and User Instructions EN Lenga 800 11 12 09 10 01 02 03 04 05 06 07 08...
Страница 33: ...33 Installation Servicing and User Instructions EN...
Страница 34: ...34...