28
Technical details
Kanda 85
Door latch
I & II
Ba
Nominal capacity*
9
kW
Fleu collar diameter
200
mm
Maximum load capacity
3
kg
* the nominal heat is obtained with a chimney draft of 0,12 mBar
Fuel, wood logs (30 x 10 cm)
Maximum supply capacity
3 pieces
Primary air valve
maximum
Secundairy air outlet
maximum
Fuel burning period
about 1 hour
Flue gas values in accordance with DIN4705, DIN 18895 part 2
Kanda 85
Flue gas quantity
9,3
g/s
Flue gas temperature
285
0
C
Pre-pressure
0,12
mBar
Efficiency
82,3
%
CO at 13% O
2
0,11
%
Particulate matter
31
mg/m
3
Certificate institute
1625
Test standard
EN13229
Test report number
RRF - 29 - 091965
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be
taken for the volume of the space to be heated:
If heating circumstances are favourable:
In less favourable circumstances:
In unfavourable circumstances:
calculate according to DIN 4701
135 m
3
95 m
3
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is
more than 8 hours.