Page | 10
Running the engine with insufficient oil can cause serious engine damage.
The Low Oil Alarm Shutdown will automatically stop the engine before the
oil level falls below a safe limit. However it is still advisable to visually inspect the oil level regularly.
Fuel
Use regular automotive gasoline with no more than 10% ethanol.
Never use an oil/gasoline mixture or dirty gasoline.
Avoid getting dirt, dust or water in the fuel tank.
After refueling, tighten the fuel filler cap securely
Gasoline vapor is invisible but is extremely flammable and is explosive under
certain conditions.
Refuel in a well-ventilated area with the engine stopped. Keep all smoking materials, sparks, and
any other source of combustion away from the generator during refueling.
Do not overfill the fuel tank, and allow for fuel to expand as it warms. After refueling, make sure the
tank cap is closed properly and securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite, If any fuel is spilled,
wipe the area is dry before starting the engine.
Avoid repeated or prolonged contact with skin or breathing of vapor.
KEEP OUT OF REACH OF CHILDREN.
Air Cleaner
Check the air cleaner element to be sure it is clean and in good condition.
Open the left side maintenance cover. Remove the
air cleaner cover, remove the paper element from the
air cleaner cover, and check the element, Replace
the element if dirty or the filter paper is torn.
Never run the engine without the air cleaner. Rapid
engine wear will result from contaminants such as
dust and dirt being drawn through the carburetor into
the engine.
Содержание WI3000P
Страница 1: ...Inverter Series Generator Operator Manual Model WI3000P May 2017 P N 220882 Rev A ...
Страница 2: ......
Страница 4: ...Page 2 ...
Страница 9: ...Page 7 COMPONENT LOCATIONS ...
Страница 24: ...Page 22 WIRING DIAGRAM WI3000P ...
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......