WP01_1_2010_de_en_fr_it_V10.doc
31 / 96
4
Stove Specifications and Functional Description
4.1
Technical data
Nominal heat output (max. / min.)
kW
8.8 / 2.4
Fuel consumption approx. (max. / min.)
kg/h
1.85 / 0.8
Level of efficiency (max. / min.)
%
92.4 / 93
Draught requirement
Pa
12
Capacity of pellet tank
kg (litre)
31 (48)
Mains supply
V
230
Frequency
Hz
50
Max. power consumption
VA
290
Power consumption during heating
VA
60
Diameter of flue support
mm
100
Weight approx.
kg
105
Dimensions (H x W x D)
mm
1080 x 560 x 510
Important note:
Note the batch number of your stove from the rating plate immediately after start-up and retain
the invoice.
We always need the article number and the batch number of your stove in
case of warranty claims or for later spare parts delivery
to ensure supply of the correct
spare parts. We assume no liability for warranty claims without specification of the batch
number and the date of purchase. Furthermore, we cannot rectify eventual faulty deliveries.
Keep all documents delivered along with your stove to facilitate eventual customer service or
subsequent ownership of the stove.
Immediately after purchase, enter the batch no. of your device:
_______________
4.2
Delivery contents
Delivery includes the following accessories:
•
Heat-resistant glove, auxiliary tools for opening the door, instructions
4.3
Functional description
A WAMSLER Pellet Stove is a special means of heating intended only for the firing of wood
pellets. During heating operation the stove produces warm air that is dissipated to the room.
Merely turn on the stove and select the preferred output level to trigger the heating mode. Upon
application of an external controller, the pellet stove could be automatically switched on and off
or the output level could be automatically adjusted. The wood pellets are fed into the burn pot in
a fully automated manner and ignited by an electric ignition system.
The controlled auger automatically feeds the correct fuel quantity depending upon the selected
heat output. The air needed for combustion flows to the burn pot in a controlled fashion. The
gases burn out in the firebox and the downstream fuel gas draughts and dissipate their heat
energy to the surroundings.
At the end of the fuel gas draught components there is an extractor fan that leads the flue gases
safely to the chimney depending upon the fuel quantity and combustion air.
The user has to remove ash and slag from the burn pot at regular intervals. Likewise, the ash
covering that always occurs during combustion of solid fuels has to be cleared from the viewing
Содержание WP 01
Страница 25: ...WP01_1_2010_de_en_fr_it_V10 doc 25 96 Installation and User Manual Pellet Stove WP 01 ...
Страница 49: ...WP01_1_2010_de_en_fr_it_V10 doc 49 96 Instructions d installation et de service Poêle à granulés WP 01 ...
Страница 73: ...WP01_1_2010_de_en_fr_it_V10 doc 73 96 Istruzioni per uso e installazione Stufa a pellet WP 01 ...