38
4 Technical data
4.1
Data
* according to DIN 18893 Tab. 2 at good / less good / poor heating conditions
All information provided by the exhaust gas values are based on the EN 12815 under stationary laboratory
conditions.
4.2
Dimensional
The specified dimensions and weights are approximate values, and thus have only informative purposes. We
reserve the right to modify the designs as required in terms of technology or quality!
Model
K139F
Nominal heat output
kW
8
Emission flow with coal
g/s
12,5 / 10,7
Flue gas temperature at exhaust socket
0
C
249 / 269
Required pressure at NHC
Pa
12
Room heat capacity* continuous heating
periodic heating
m
3
260 / 145 / 98
182 / 105 / 71
Flue gas connection diameter
Ø mm
120
Dust (based on 13% O
2
)
mg/m³
≤ 40
CO (based on 13% O
2
)
mg/m³
≤
1250
CO (based on 13% O
2
)
%
≤
0,12
OGC (based on 13% O
2
)
mg/m³
≤ 120
NOx (based on 13% O
2
)
mg/m³
≤ 170
Efficiency
%
75,3 / 75,4
Содержание K 139F