the burning space. This in fact means smoke and soot-poor burning, which
contributes to the protection of the environment. If you wish to commission the
fireplace in a transitional period, please, please first examine the chimney draught,
as it can be especially weak at high external temperatures. Towards this end, hold a
burning match in the slightly opened feeding door. If the flame is not drawn
significantly by the draught, then a so-called starting fire is to be set first. Towards
this end, burn wood chips/wool in the fireplace or the cleaning hole of the chimney.
The fire grate is to be cleaned before every kindling to ensure the proper inflow of air
for burning. The ashtray is to be emptied regularly. Should the equipment be
extremely hot, use the gloves (pic. 4). Please, be careful not to dispose glowing
materials into the waste bin.
Ensure that the ashtray should be fully pushed into the equipment.
Warning!
In order to keep the air clean and safeguard the fireplace, do not exceed
the specified maximum fuel quantity, otherwise overheating may occur, which
potentially damage the equipment. Such damage is not covered with any guarantee.
Only a single layer of fuel is allowable to be prepared in the fireplace. Try to reach
lower heating performance only by decreasing the quantity of fuel, and not by cutting
the primary air supply.
1.5 Cleaning and maintenance
After the heating season, it is recommended to clean the fireplace and the flue gas
pipes carefully. Any dropping heating performance is almost always the
consequence of the strong contamination of the flues. For cleaning, the baffle plate
is to be pulled forward. This way, the flues can be cleaned from the inside or – after
removing the flue gas pipe – from above. After cleaning, the baffle plate is be
pushed back fully again.
Warning!
Following every heating season you are advised to examine the fireplace thoroughly.
If any repair or reconditioning is needed, please, contact your local dealer in a timely
manner, and specify the model number and serial number of your equipment (as
seen on the model plate). External surfaces may be maintained only after the
fireplace cooled down, and following the first commissioning. Use cold water for
cleaning, or soap, washing ingredient in extraordinary cases, then wipe it dry. Before
its first use, clean the ROBAX inspection glass with a wet and clean cloth, and then
put a few drops of glass–ceramics cleaner onto both sides of the glass, and spread
them with the use of kitchen paper tissues. It provides an invisible film on the
valuable surface of the Robax glass. This film helps to keep the glass clean, and
facilitates regular cleaning operations. ROBAX S for slightly contaminated surfaces –
a commercially available glass surface cleaning agent – may as well be used for the
cleaning of the medium or strongly contaminated glass surfaces of the fireplace.
Towards this end, spray small quantities of the agent to the cold surfaces, spread it,
and wash it down with a wet cloth, followed by drying with a clean, soft cloth. In case
there are sticky fuel deposits on these surfaces, first scale simply them with a
ceramic-plate scraper held in flat angle, and then clean the surfaces as described
above.