33
3. Technical specification
3.1 Dimensional drawings
111 10 F-BOX
The specified dimensions and weights are approximate values, and thus have
only informative purposes. We reserve the right to modify the designs as required
in terms of technology or quality!
Type 113
10
Nominal performance
8 kW
Heating capacity (m
3
)
-under favorable
-less favorable
-not favorable heating circumstances
according to 18893/TAB2 DIN standard
182
105
71
Flue gas values: fuel:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at nominal performance:
Dust (relating to 13% O
2
)
CO (relating to 13% O
2
)
Efficiency
WOOD / BB7”
6,9 / 7,5 g/s
312 / 336
0
C
12 Pa
< 40 mg/m³
955 / 592 mg/m
3
80,1 / 78,6 %
Содержание 113 10 F-BOX
Страница 17: ...17...
Страница 18: ...18...
Страница 27: ...27 pic 3 pic 4 pic 5 pic 6 Furnace chamber walling open closed...
Страница 73: ...73 3 k p 4 k p 5 k p 6 k p Falazat Terel lapok...