24
14.
When in use, all surfaces and particularly the glass doors and handles and
other controls can become very hot. Make children, young people, older people
and animals aware of this danger, and keep them away from this source of heat
when the stove is being used. Use the protective gloves or the implements pro-
vided. Children and young people under 16 must not use the stove unless su-
pervised by an adult who is responsible for them.
15.
Make sure that the ash pan is always fully pushed in, until it touches the back.
Never remove ashes while still hot (fire risk).
16.
In spring and autumn the chimney may no longer draw correctly, so that gases
produced by combustion are not completely removed. The fire chamber should
then be filled with a small quantity of fuel, ideally with wood shavings, and lit
under supervision, in order to stabilise the chimney draught. The grate must be
clean.
17.
After each prolonged period of use for heating, have the stove checked by a
professional. The flues and pipes for the evacuation of fumes must also be
thoroughly cleaned.
18.
If repairs or replacements are necessary, please contact your supplier with the
necessary article numbers and serial numbers in good time. Only original
WAMSLER replacement parts may be used.
19.
Work such as installation, setup, commissioning and services, as well as re-
pairs, must only be carried out by qualified personnel (heating system or space
heating technicians). Intervention by non-qualified persons invalidates the war-
ranty and guarantee.
20.
As the solid fuel oven/stove draws the air required for combustion from the
surrounding room, you must ensure that sufficient air can be drawn in through
non-sealed windows and outside doors. It can be assumed that is this is pro-
vided by a room volume of at least 4 m³ per kW nominal heat capacity. If the
volume is less than this, then air vents can be used to provide access to further
air in other rooms (min. 150 cm²).
21.
You must ensure that the correct safety distance is maintained from all flam-
mable components and materials – to the side, rear and front. These distances
can be found in the Instructions for Use or the identification plate.
22.
The fire chamber must not be modified.
23.
Connection to a chimney whose functional height is less than 4 m, or if multiple
stoves are installed, 5 m, is not permitted. A maximum of two other fires can be
connected to the chimney which is to be connected the stove.
24.
If the chimney catches fire immediately close all doors and openings and call
the fire brigade. Do not attempt to extinguish the fire yourself. Afterwards have
the chimney thoroughly checked out by a professional.
25.
Solid fuels naturally create soot, so it is always possible that the window glass
will become dirty: this does not mean there is a malfunction
.
Содержание 108 30 OPHIT
Страница 5: ...5 1 Bedienung 1 1 Ger teaufbau...
Страница 11: ...11 Bild 2 Bild 3 Bild 4 Bild 5 Bild 6...
Страница 15: ...15...
Страница 17: ...17 Externer Luftan schlu 100 mm...
Страница 18: ...18 3 Technische Daten 3 1 Ma zeichnungen OPHIT PYRIT JENA...
Страница 19: ...19 TRIGO HELIX...
Страница 21: ...21...
Страница 25: ...25 1 Usage 1 1 Structure of the equipment...
Страница 30: ...30 picture 2 picture 3 picture 4 picture 5 Protection corrugated paper for transporta picture 6...
Страница 36: ...36 3 Technical specification 3 1 Dimensional drawings PYRIT JENA OPHIT...
Страница 37: ...37 TRIGO HELIX...
Страница 48: ...48 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 l ment retirer avant la mise en service...
Страница 53: ...53 3 Donn es technipues 3 1 Plans avec les dimensions PYRIT JENA OPHIT...
Страница 54: ...54 TRIGO HELIX...
Страница 73: ...73 D aria bocchettone 100 mm...
Страница 74: ...74 3 Schede tecniche 3 1 Disegni dimensionali e dati PYRIT JENA OPHIT...
Страница 75: ...75 TRIGO HELIX...
Страница 80: ...80 1 Haszn lat 1 1 A kandall fel p t se...
Страница 92: ...92 3 M szaki adatok 3 1 M retrajz PYRIT JENA OPHIT...
Страница 93: ...93 TRIGO HELIX...