5.0 INSTALLATION AND FIXING
ILV
2
TOR.056.--.M.EN Issue: A1
09.16
25
5.6 Adjusting the indicator
MINIMUM / MAXIMUM SAFETY LEVEL
ELECTRONIC BOARD
5 4 3
2 1
8 7 6
FSH
FSL
A
B
If the probe is used to indicate the full load status, set the maximum safety level on FSH. Drop in current or line
interruptions are interpreted as a “full” signal (overload protection).
If the probe is used to indicate the empty status, set the minimum safety level on FSL. Drop in current or line
interruptions are interpreted as a “empty” signal (protection against empty running).
8 7 6 5 4 3
8 7 6 5 4 3
3 1
3 1
FSL
FSH
Setting
Relay DTPT
3-wire PNP
LED "Signal output"
8 7 6 5 4 3
8 7 6 5 4 3
3 1
3 1
FSL
FSH
Signal Output - ILVA - ILVB