5 Initial Start-up
5.1 Mounting and Installation
The spraying device can be installed in any position.
The distance of the nozzle to the application surface depends on the required spraying width. The larger the
distance of the nozzle to the application surface, the larger will be the spraying width of the material.
Make sure that the spraying device is secured fastened on the holder or in machine!
Intermitting processes can cause vibrations.
Machine vibrations to the valves and from the valves to the machine should be avoided in order to achieve a
clean and accurate application surface.
Vibrations of the valve caused by fast intermitting cycles require solid and tight installation. Machine
vibrations to the valves should be avoided.
5.2 Hose Mounting
Control air and material will be supplied to the spraying device via two separate connections. The following
markings are used:
Control air -open-
(black)
Connection S : to 3/2-way magnetic valve (without closing air)
2x to 5/2-way magnetic valve (with closing air)
Material (transparent or white)
Connection M : to pressured container or pump
CAUTION
In order to avoid malfunctions or damages on the spraying device or the system, make
sure that all pressured lines are correctly assigned and connected to the hose connec-
tions at the spraying device.
Please observe prior to initial start-up:
Turn on energy supply
Turn on supply for atomizer air, control air and material
Use control unit to start device
Check correct function and proper operation of device
Check if device operation stays within all pre-set parameters
After checking that the device is properly functioning, it can be employed with due regard to the guiding
safety and accident prevention directives.
Sound absorber
Material
Control air
–open-
(w/o closing air)
Important!
For use (with closing air) the
sound absorber has to be
removed and will be replaced by
an additional hose connection.