background image

14 

 

10 

Accessories

Accessories 

A) Selection and mounting of the cleaning

pads and tips

Tungsten tips are made from high quality tungsten alloy 
material. Other materials will not resist the harsh environ- 
ment created by the electrochemical process.

Threaded c

arbon fiber brushes 

Part no: 54-B 155 

Triangular shape 

Part no

:

 54-B 156 

Round shape 

5 per package 

Ideal for tight corners, 
narrow surfaces and 
intricate areas 

TIP

. Resurface the insert using a bench grinding

wheel or angle grinder. 

Note: 

Be sure to install the O-Ring located at the back of the insert 

whenever they are changed. 

O-Ring

Worn edges on insert. 

Inserts 

Tungsten insert 90° 
No: 54-B 143 

Use with cleaning pad 54-B 026 
or 54-B 040 and clamp ring 54-B 002 
or boot 54-B 005. 

Large graphite insert 
No: 54-B 009 

Use with large cleaning pad 54-B 043 

Ideal for large welded areas 
and for surface renovation. 

Narrow tungsten insert 90° 
No: 54-B 017 

Use with cleaning pad 54-B 028 or 
54-B 041 and clamp ring 54-B 020
or boot 54-B 007.

WARNING

When the insert is too worn, it can

cause damage to the cleaning pads. 

Содержание SURFOX 305

Страница 1: ...SURFOX 305 User s Guide...

Страница 2: ......

Страница 3: ...ode 9 E Cleaning and passivating 9 F Neutralizing 9 7 Using the mini wand optional to clean and passivate 10 10 10 10 A Selecting the proper mode B Selecting the proper current type AC or DC on stainl...

Страница 4: ...intaining this valuable invest ment With proper care and maintenance your SURFOX equipment will provide years of dependable service To learn more about the other WALTER products visit our website walt...

Страница 5: ...ure the switch is in its OFF position before plugging in or when moving the unit to avoid unintentional starting 15 Hold the wand rmly Do not overreach maintain good footing and balance at all times 1...

Страница 6: ...recompletelyemptyand all connecting lines disconnected The machine must be carefully packed in a suitable container and properly protected WALTER will not be held responsible for any damages resulting...

Страница 7: ...and solution supply lines Connect the hose to the adaptor by rotating the quick connect part of the hose clockwise and making sure the white dot ends in the locked position Accessory Outlet Marking a...

Страница 8: ...ing in con ned areas To activate this feature simply connect a compressed air line 150 PSI max 80PSI min to the tting at the back of themachine Thefumeeliminationsystemisautomatically activated when t...

Страница 9: ...Level 2 is for MIG welds Level 3 should be used with a lot of electrolyte solution with the air system only For marking or etching select AC for marking and DC for etching Level 1 has the lowest amper...

Страница 10: ...akesuretoletliquid owfor2minutes Themachinewill stopafter30secondswhennocurrentis owingthrough This mean you will have to press the ON button on the large wand 4 times to complete the purge C Connecti...

Страница 11: ...mode To start the automatic pumping mode press the ON button on the wand Once it is activated it will automatically pump the liquid The quantity of liquid can be selected from less to more E Cleaning...

Страница 12: ...the power to the hand wand stops the solution pumpandthefumeeliminationsystem ifconnected from operating Only poweris provided to the mini wand marking wand outlet Be sure work piece is grounded B Sel...

Страница 13: ...RFOX T electrolyte cleaning solution 100 ml Part no 54 A 001 6 per package SURFOX G electrolyte cleaning solution 100 ml Part no 54 A 061 6 per package Threaded brush adaptor Part no 54 B 150 1 per pa...

Страница 14: ...king useDCandSURFOX Etomakeanetching Onaluminum use AC and SURFOX M ALU to make a black marking and DC and SURFOX E to make an etching On titanium use AC and SURFOX M to do a blue marking INOX STAINLE...

Страница 15: ...d be kept moist not dripping 1 After weld cleaning use a clean cloth or paper towel and wipe the affected area in a squeegee action from left to right Then discard the cloth or paper towel You could a...

Страница 16: ...rt using a bench grinding wheel or angle grinder Note Be sure to install the O Ring located at the back of the insert whenever they are changed O Ring Worn edges on insert Inserts Tungsten insert 90 N...

Страница 17: ...OX N at the end of each working day Cleaning pads are available in three sizes Standard cleaning pad No 54 B 026 Use with insert 54 B 143 Inside corners cleaning pad No 54 B 027 Use with insert 54 B 0...

Страница 18: ...aning systems SURFOX G pH NEUTRAL Electrolyte Cleaning Solution Cleans up to 3 5 feet per minute 1 5 L 50 7 oz 54 A 065 STD Pack 1 STD Carton 4 5 L 1 3 gal 54 A 066 STD Pack 1 STD Carton 1 20 L 5 2 ga...

Страница 19: ...ing temperature is too high the machine will shut down the corresponding LED on the front panel with light and the unit will restart by itself when the temperature reaches an acceptable level The corr...

Страница 20: ...nductivity in the material the SURFOX system cannot work If there are two welds on top of the other the structure of thematerialhasbeenseriouslyaltered Theseareas may not be cleaned The quality of the...

Страница 21: ...sorreplacements havebeenmadeorwere attempted by anyone other than WALTER authorized service personnel and does not cover any damage caused by accidents modi cations use of improper accessories abuse o...

Страница 22: ...walter com...

Отзывы: