Walrus TP3 Series Скачать руководство пользователя страница 3

SPECIFICATIONS

Model No: 
Output(W)
Cycle(Hz)
Revolution
Suction head(m)
Total head(m) 
Total capacity(L/min) 
Inlet (mm)
Outlet (mm)
Package size (mm)
Gross weight (kg)

TP320

370

50              60

2850         3420

6

32              43

60

20(¾")
20(¾")

290x210x220

7.5

TP325

370

50              60

2850         3420

6

32             43

60

25(1")
25(1")

290x210x220

7.5

TP330A

750

50              60

2850         3420

6

41              38

65/75
25(1")
25(1")

350x260x250

11

a. Check the electrical power source, 

fuse, and circuit breaker.

b. Check if pump is locked by rust or 

foreign objects.

c. Check if the ventilation of the 

location is bad for causing the 
overheating of motor.

2. When charge pump with electricity 

and the pump revolve normally but 
you find no water supply, please 
check it as followings.

a. The pump casing should be full of 

water , if shortage, please open 
the water plug (FIG.3-11) and pour 
into water anew till quite brimming.

b. If water is leaking out from the pipe 

please install again there's a 
blockade in the drain-pipe, please 
clean it out.

3. If you can't get rid of the bug, 

please call to sales agent or the 
distributive service station.

Coverage of Application:

To be used on supplying water:

1. For the apartment and residences.
2. For the heater and agricultural 

irrigation.

3. For the garden pump and sprinkle 

water. 

~ 2 ~