Walrus TP3 Series Скачать руководство пользователя страница 2

OPERATION

FIG.1

1. Make sure of using the right voltage.
2. Remove the water plug and pour 

water into the pump and suction 
piping ,then secure the plug.

3. Insert a screw driver cross into the

shaft slot , and turns the shaft 2-3 
rounds to check if the pump runs 
normally , then open one faucet on 
the delivery side , the turn the power 
switch ON.(FIG.1)

4.  After the power switch on, the motor  

should turn immediately . After a few 
seconds, the water should be 
delivered. 

5. If the water does not be delivered 

immediately turn the power OFF. 
Repeat step 2 and set power ON/OFF 
continuously to make the suction 
piping be filled with water.

IMPORTANT NOTE

1. Use the right voltage and wiring by 

the connecting diagram. Motor must 
be grounded in compliance with   
applicable electrical code to avoid 
accident.

2. please use a sturdy foundation and 

bolt the pump to it securely.

3. Be sure to arrange earthling or circuit 

breaker against electric leakage.

4. The pump should be installed as 

close as to the reservoir or well to 

avoid the low efficiency due to the 

long suction pipe. 

5. The location must be dry with good 

ventilation and adequate space. 

6. Do not run without water actually 

pumping.

Do not operate hot water (more than

60 C), or the other liquid except 

normal water.

7. Be careful not to allow the foreign 

matter (chips, dirt, sand, glue, etc) 

into the pump, or the will damage and 

shorten the life of pump.

8. Piping joints should be fitted carefully 

to prevent leakage.

a. Leakage in the suction piping will 

cause the pump does not function 

well.

b. If an "outlet for water " is leaking 

out, then the water pressure will 

be lowered.

9. Please  install  a  check  valve  on 

suction piping.

TROUBLE SHOOTING 

(Turn the power switch OFF before 
fixing.)

1. MOTOR  FAILS  TO  START  OR 

RESTART AFTER A SHORT-TERM 
RUNNING

    The overheating protector is mounted 
directly on the motor windings. It will 
stop the motor automatically when the 
motor temperature is up to abnormal, 
and restart the motor after the 
temperature back to normal in 20 
minutes.

O

~ 1 ~

Отзывы: