•  Installation and electrical connection have been 

completed properly.

•  The cable glands have been tightened.

•  Residual material from the installation and foreign 

bodies have been removed from the speed gover-

nor and the ducts.

•  The data on the type plate corresponds to the 

connection data.

•  Before switching on, check the speed governor for 

visible damage and ensure that the protective 

devices are functioning properly.

10.  Disposal

• 

Ensure that the material is recycled. Observe the national regulations.

• 

The unit and the transport packaging consist mainly of recyclable raw materials.

11.  Spare parts

• 

Only use original spare parts from Walpol!

• 

When ordering spare parts, state the serial number of the speed controller. This is indicated on the type plate.

12.  EU Declaration of Conformity

The manufacturer:

Walpol GmbH
Benzstr. 13
45891 Gelsenkirchen

Product designation:

Speed controller

Type designation:

WPO

Serial number

All Manufactured

From year of manufac-

ture:

2005

The manufacturer declares that the above-mentioned products in their design and construction as well as the version mar-

keted by

us comply with the harmonisation regulations listed below:

Содержание WPO55

Страница 1: ...Potentiometer speed control units Assembly and operating instructions Version 6 1 B14...

Страница 2: ...Warranty 4 4 Delivery transport storage 4 5 Description 5 5 1 Speed controller type WPO 55 5 5 2 Speed controller type WPO 5 6 Installation 6 7 Electrical connection 7 8 Connection diagram and functio...

Страница 3: ...ditions and requirements of the system manufacturer or system builder Safety devices must not be dismantled bypassed or rendered inoperative The speed controller may only be used if it is in perfect c...

Страница 4: ...ort circuit 5 Cover or isolate adjacent live parts Disconnect the device from the power supply and secure it against being switched on again Check that there is no voltage using a two pole voltage tes...

Страница 5: ...5 stages by means of a rotary knob It has a switch dry contact for remote ON OFF switching of external devices The potentiometer is suitable for surface mounting IP55 Type Dimensions height x width x...

Страница 6: ...Take all static and dynamic loads into account Connect the unit only to permanently laid cables Electrical connection only in accordance with the currently valid VDE and EN guidelines as well as TAB s...

Страница 7: ...ectrical installations Prevent water from entering the terminal box The electrical connection may only be carried out by suitably qualified persons for details see table Qualification Regulations Acci...

Страница 8: ...ellen Einstellen der Stufen 1 5 8 2 Speed controller WPO infinitely variable Wiring diagram 3 Us supply voltage 0 12 VDC 4 output voltage 0 5 ground 1 2 Dry contact for remote ON OFF connections Cable...

Страница 9: ...the national regulations The unit and the transport packaging consist mainly of recyclable raw materials 11 Spare parts Only use original spare parts from Walpol When ordering spare parts state the se...

Страница 10: ...10 Place Gelsenkirchen Date 01 012 2021 Maximilian Girnus Managing Director WALPOL GmbH...

Страница 11: ...emissions CEI EN 55014 1 Measurement of harmonic current emissions CEI EN 61000 3 2 Detections of voltage fluctuations FLICKER CEI EN 61000 3 3 Application of electrostatic discharge EDS CEI EN 55014...

Страница 12: ...ww eu...

Отзывы: