background image

 

 

   

 

 

Revision 5 

14 

Product Manual  
WHBV-101W-LH-NB and WHBV-101W-RH-NB 

 

5.4 Mounting the Washbasin 

WARNING! 

To maintain the anti-ligature & anti-vandal properties of this 

product it must be installed in line with the following points. 

 
1.  Ensure product fixings are correctly fitted as detailed in the following instructions. 
 
2.  Ensure all fixings are tightened to the recommended torque as detailed in the 

following instructions. 

3.  Seal the edges of the product to the wall using an approved, anti-pick hard set 

mastic. 

To mount the washbasin to the wall: 
 
1.  Attach the side support angle brackets (Item 2, figure 5) to the basin using the 

M10X16 bolts (Item 7, figure 5) provided and tighten them to the recommended 
torque of 20Nm. (A thread locker can be used, depending on the installation site). 

2.  Lift the washbasin into position and sit it on the end support bracket (Item 1, figure 

5) fixed to the wall.

 

Insert the waste pipe and water pipe into the correct apertures 

in the wall. Check that the wall fixings for the bracket line up with the respective 
holes in the brackets (Item 2, figure 5). 

3.  Once the positions have been checked, make sure the basin seats flush against 

the wall. The side support angle brackets (Item 2, figure 5) can be adjusted 
forwards or backwards if necessary. If loosened refer to point 1 for the 
recommended torque. 

4.  There is room to tighten the wall fixings used on the side support angle brackets 

via access on the base of the product. Before fully torquing the fixings, adjust the 
position of the basin so that: 

a.  The basin weight is not supported on the water supply tube which may 

damage the water seal on the push fit connector. 

b.  The basin is level both horizontally & vertically. 

5.  Once in its final position, the end support bracket (Item 1, figure 5) can now also 

be attached to the basin using the fasteners provided. The recommended torque 
is 8Nm for the M6X10 bolts used (Item 6, figure 5). (A thread locker can be used if 
required.) 
 

6.  After the basin has been fully secured to both walls, the bottom cover panel (Item 

3, figure 5), can be attached to the bottom of the basin. The recommended torque 
for the bolts (Item 6, figure 5) is 8Nm. (A thread locker can be used if required.)  

7.  Apply an approved, anti-pick hard set mastic to basin edges against the wall. 

Содержание WHBV-101W-LH-NB

Страница 1: ...Product Manual WHBV 101W LH NB and WHBV 101W RH NB Washbasin with Integral Tap...

Страница 2: ...Revision 5 2 Product Manual WHBV 101W LH NB and WHBV 101W RH NB...

Страница 3: ...2 5 Menu items 5 3 Glossary 6 4 Overview 6 5 Installation and Commissioning 7 5 1 Package Contents 7 5 2 Site Preparation 7 5 2 1 Mounting Guidelines 7 5 3 Preparing the Washbasin 12 5 4 Mounting the...

Страница 4: ...NZS 3500 the PCA and your local regulatory requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provis...

Страница 5: ...ngs before you install and commission the wash basin Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is us...

Страница 6: ...r anti ligature products have been designed to reduce the likelihood of a ligature attachment however it is the responsibility of the purchaser or service provider to ensure it is risk assessed and su...

Страница 7: ...ation 5 2 Site Preparation 5 2 1 Mounting Guidelines The washbasin must be attached to a vertical surface that can support the weight of the washbasin See Table 1 on page 16 for the weight Refer to Fi...

Страница 8: ...Revision 5 8 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 1 WHBV 101W RH NB Basin Details...

Страница 9: ...Revision 5 9 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 2 WHBV 101W LH NB Basin Details...

Страница 10: ...Revision 5 10 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 3 Wall hole sizes positioning for WHBV 101W RH NB...

Страница 11: ...Revision 5 11 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 4 Wall hole sizes positioning for WHBV 101W LH NB...

Страница 12: ...aptor Item 8 figure 5 into the integral push fit connection on the basin inlet and attach a water supply pipe The water supply connection is provided on site by others Site conditions and the type of...

Страница 13: ...Revision 5 13 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 5 Components and assembly details for the WHBV 101W RH NB...

Страница 14: ...pective holes in the brackets Item 2 figure 5 3 Once the positions have been checked make sure the basin seats flush against the wall The side support angle brackets Item 2 figure 5 can be adjusted fo...

Страница 15: ...ebris and trapped air NOTE Fit a Y strainer in the water supply feed pipe before connection to the washbasin especially on older installations where loose particles from ageing water pipes can cause a...

Страница 16: ...rged from the system and to ensure that the flow rate is correct 5 7 Technical Specifications Table 1 Technical specifications Weight Approximately 35Kg Dimensions 720mm W x 310mm H x 440mm D Water Su...

Страница 17: ...n be obtained from our customer service department 6 1 Maintenance General wear mainly affects the components in contact with water If the unit is installed in a hard water area lime scale may need to...

Страница 18: ...the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the M...

Страница 19: ...el 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com Galvin Engineering Pty Ltd 410 Victoria Road Malaga Western Australia 6090 Australia tel 61 8 9338 2344 fax 61...

Отзывы: