Revision 5
14
Product Manual
WHBV-101W-LH-NB and WHBV-101W-RH-NB
5.4 Mounting the Washbasin
WARNING!
To maintain the anti-ligature & anti-vandal properties of this
product it must be installed in line with the following points.
1. Ensure product fixings are correctly fitted as detailed in the following instructions.
2. Ensure all fixings are tightened to the recommended torque as detailed in the
following instructions.
3. Seal the edges of the product to the wall using an approved, anti-pick hard set
mastic.
To mount the washbasin to the wall:
1. Attach the side support angle brackets (Item 2, figure 5) to the basin using the
M10X16 bolts (Item 7, figure 5) provided and tighten them to the recommended
torque of 20Nm. (A thread locker can be used, depending on the installation site).
2. Lift the washbasin into position and sit it on the end support bracket (Item 1, figure
5) fixed to the wall.
Insert the waste pipe and water pipe into the correct apertures
in the wall. Check that the wall fixings for the bracket line up with the respective
holes in the brackets (Item 2, figure 5).
3. Once the positions have been checked, make sure the basin seats flush against
the wall. The side support angle brackets (Item 2, figure 5) can be adjusted
forwards or backwards if necessary. If loosened refer to point 1 for the
recommended torque.
4. There is room to tighten the wall fixings used on the side support angle brackets
via access on the base of the product. Before fully torquing the fixings, adjust the
position of the basin so that:
a. The basin weight is not supported on the water supply tube which may
damage the water seal on the push fit connector.
b. The basin is level both horizontally & vertically.
5. Once in its final position, the end support bracket (Item 1, figure 5) can now also
be attached to the basin using the fasteners provided. The recommended torque
is 8Nm for the M6X10 bolts used (Item 6, figure 5). (A thread locker can be used if
required.)
6. After the basin has been fully secured to both walls, the bottom cover panel (Item
3, figure 5), can be attached to the bottom of the basin. The recommended torque
for the bolts (Item 6, figure 5) is 8Nm. (A thread locker can be used if required.)
7. Apply an approved, anti-pick hard set mastic to basin edges against the wall.
Содержание WHBV-101W-LH-NB
Страница 1: ...Product Manual WHBV 101W LH NB and WHBV 101W RH NB Washbasin with Integral Tap...
Страница 2: ...Revision 5 2 Product Manual WHBV 101W LH NB and WHBV 101W RH NB...
Страница 8: ...Revision 5 8 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 1 WHBV 101W RH NB Basin Details...
Страница 9: ...Revision 5 9 Product Manual WHBV 101W LH NB and WHBV 101W RH NB Figure 2 WHBV 101W LH NB Basin Details...