8
Product Manual WDC200 Electronic Control
Revision 18
4. Product summary
The WDC200 electronic control units are designed to operate the water outlets to a
wash basin* (x2) (Hot & Cold), a shower (x2) (premixed warm water) and the flush
for toilet water closet pan (x2) (WC). The WDC200 therefore has the capacity to
control two suites of products and can be located between two rooms.
*The WDC200 can be set to operate with a bath instead of a basin if required. This
would entail the installer or client adjusting water run times to 180 seconds for hot
and cold, or as preferred.
The WDCA200 model based upon the WDC200 is for 120v 60Hz electrical supply
operation using an external power adapter (UL/CSA approved) to connect to the
12VDC input socket on the WDCA200 control unit.
The control unit comprises of a microprocessor that is programmed with a software
program that has the following operational features:
•
User friendly Software menu system with security controlled access.
•
Independent control of multiple outlets.
•
Fully programmable precise time control of water valve operation that is fully
adjustable in situ by the installer / customer.
•
“
LOCKOUT
” function to prevent product misuse that is fully adjustable for the
number of user operations, operations period, lockout period, and the
“
LOCKOUT
” function can be
ENABLED
or
DISABLED
to suit the individual
requirements.
•
Single or dual flush for WC control.
•
Piezo touch button or infrared sensor capable inputs.
•
Auxiliary inputs for remote operation of:
•
Remote lockouts (Room 1 / Room 2).
•
WC remote flush.
•
WC reduced flush using a second touch button.
•
Clear lockouts.
•
Purge function.
•
Not used
•
Flow sensor for hygiene purge data logging.
•
Multiple outlet control feature (
COMMUNAL
mode setting), so that one unit can
be used to operate up to eight water valves instead of default pre-sets for basins
and WC pans.
•
Diagnostic test routine to assist with fault finding.
•
Networking units to remotely control from a central PC desk position(s).
•
Data logging of hygiene purges.