16
Product Manual WDC200 Electronic Control
Revision 18
then this can be adjusted by amending the Lockout Mode setting from 1 to 2, see
section 7 for menu list.
Default settings are as follows. These can be reconfigured as required.
•
1 hour for basin/bath and shower.
•
15 minutes for the WC pan.
To cancel the
Lockout
function when it has been activated due to excessive
operations and allow the unit to operate normally again, carry out the following steps:
Switch off the power to the control unit for 5 seconds.
Switch on the power to the control unit.
–or–
Activate the ‘clear lockout’ function via an auxiliary input.
Check that the basin, showers and WC are operating correctly.
5.11.
Piezo touch button and infrared sensor controls
Piezo touch buttons and infrared sensors can be connected to the control unit to
operate the basins, showers and WCs. You can connect either Piezo touch buttons
or infrared sensors to the control unit.
The control unit is set for use with Piezo touch buttons by default.
If you connect infrared sensors to the control unit, you must modify the applicable
setting. For instructions on how to do this, refer to Table 6 on page 23. You do not
have to modify this setting if the control unit is factory set for operation with infrared
sensors.
The Piezo touch buttons do not have any moving parts.
To operate the Piezo touch button:
Press the centre of the button to start the operation.
Press the centre of the button to stop the operation (for basin hot and cold only).
To operate the infrared sensor:
Hold your hand within 50mm of the infrared sensor.
NOTE: Infrared sensors cannot stop or interrupt an operation until the
operation is complete. Piezo pushbuttons can interrupt or stop an operation.
For example, you can interrupt a basin operation by pressing the piezo button
again. You cannot interrupt a basin operation by operating the infrared sensor
again.