5.2.4 Method 3: Cast in Box
(See Figure 5):
1. Cast ceiling mounting box into ceiling ensuring flanges are flush with the ceiling.
NOTE: Box size: 80x80x65mm.
2. Fit the 4 x M5 screws (Item 3, Fig: 2) through shower plate into ceiling mounting
box. Tighten each screw to a torque of 3.5Nm, a thread lock can be applied
(Loctite 222).