5.3. 

Connecting Services to the Bath 

 
Follow the instructions to connect services to the bath: 

 

NOTE: Flush the water supply pipes to remove any debris and trapped air. 
      
NOTE: Fit a Y strainer or similar in the feed pipes before connection to the 
solenoids, especially on installations where loose particles from older pipe 
work can cause a blockage in the valves & taps.  
 
NOTE: Fit a service isolating tap on the feed to each solenoid. This allows easy  
maintenance when required. The isolating tap is not supplied by Wallgate. 
 
NOTE: Pipe sealing compound should be avoided. If it is used, it should be 
used sparingly. To prevent blockages and damage to the bath tap aerators and 
water solenoid valves. 

 

1. 

Tap Head:

 On the pre-installed bath mounted tap head, fit the two push fit 

22mm x ¾” BSP straight push fit connectors onto the protruding ¾” BSP water 
inlets. Then tighten nuts to 4Nm. 

 

2. 

Bath waste:

 

a.  Fit the supplied seal washer under the chrome rim of bath waste. Insert 

the bath waste spigot through the bath outlet hole from the top inside of 
bath. 

 

NOTE: If required to ensure a water tight bath waste fitting use a suitable 
sealant. 

 

b.  Install the 2

nd

 seal washer onto the protruding bath waste spigot. 

Orientate and fit the overflow housing open face against 2

nd

 seal 

washer. Fit nut onto spigot and tighten. Push the top end of overflow 
pipe onto protruding pre-fitted bath overflow spigot.

 

 

3. 

Solenoid Valve:

 

 

a.  On the valve, note direction of water flow and keeping the solenoid 

valves in a horizontal & coil upright orientation, with 22mm x 

¾” push fit 

connectors fitted and tightened to 4 Nm. Push fit 22mm hot and cold 
pipes from solenoid to tap head.

 

 
 
 
 

Содержание ALB-01

Страница 1: ...Product Manual ALB 01 03 05 Solid Surface Bath Tap Electronic Control ...

Страница 2: ...Revision 3 2 Product Manual ALB 01 03 05 AS 3498 Certificate No 23167 ...

Страница 3: ...s 5 3 Glossary 6 4 Overview 6 5 Installation and Commissioning 7 5 1 Package Contents 7 5 2 Site Preparation 7 5 2 1 Installation Guidelines 8 5 3 Connecting Services to the Bath 12 5 4 Fitting the Side Panels 15 5 5 Commissioning for use 15 5 6 Technical Specifications 16 6 User and Maintenance Instructions 17 6 1 Operation 17 6 2 Maintenance 18 7 Related Documentation 18 ...

Страница 4: ... any time without prior notice This manual is specific to the product that it has been supplied with at the date of supply Without prejudice to any warranties in Wallgate Limited s terms and conditions of sale any warranty will be invalidated if the equipment is installed or serviced by unqualified personnel No part of this publication and the information contained may be reproduced transmitted st...

Страница 5: ...ore you install and commission the bath Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is used to draw your attention to important and useful information NOTE This is a note 2 3 Numbered procedures Steps in procedures are numbered starting from 1 1 This is step 1 2 This is step 2 etc 2 4 Bullet lists A b...

Страница 6: ...ndard Pipe BSP thread is a family of standard screw thread types that has been adopted internationally for interconnecting and sealing pipe ends by mating an external male with an internal female thread Y Strainer Accessible inline pipe filter housing for removal of rust scale and other pipe debris from water flow by means of perforated or wire mesh Description sourced from Wikipedia at http en wi...

Страница 7: ... BSP push fit straight tap connectors 2 off solenoid valves cables Supplied with 4 off 22mm x BSP push fit connectors 2 off ø22mm x 100mm long copper pipes 1 off Electronic Control Unit model WDC100 1 or optional WDC200 1 off Bath Installation sheet to suit relevant side panel set 1 off Bath Frame Optional extra sold separately 1 off Bath panels with fixing screws Note panels supplied will vary ac...

Страница 8: ...Sikadur 33 manufactured by SIKA Ltd www sika co uk 5 2 1 Installation Guidelines The bath must be attached to a frame see Fig 1 mounted on a level floor suitable for supporting the bath tub water and occupant See Table 1 for the weight Refer to Figures 2 and 3 for a typical installation of the bath Hot and cold water supplies are necessary See Table 1 for the specifications of the water supplies F...

Страница 9: ...equired see Figure 3 DETAIL F WARNING The bath alone weighs approx 70Kg Always use safe lifting procedures when lifting heavy loads Make sure the bath is correctly supported and located to frame and wall NOTE Make sure you do not abrade or damage the cables water waste pipes when mounting the bath into position or when inserting them through the walls etc ...

Страница 10: ...Revision 3 10 Product Manual ALB 01 03 05 Figure 2 Typical Bath Installation sht 1 ...

Страница 11: ...Revision 3 11 Product Manual ALB 01 03 05 Figure 3 Typical Bath Installation sht 2 ...

Страница 12: ...p Head On the pre installed bath mounted tap head fit the two push fit 22mm x BSP straight push fit connectors onto the protruding BSP water inlets Then tighten nuts to 4Nm 2 Bath waste a Fit the supplied seal washer under the chrome rim of bath waste Insert the bath waste spigot through the bath outlet hole from the top inside of bath NOTE If required to ensure a water tight bath waste fitting us...

Страница 13: ...ig 3 5 Control Unit a An electrical supply of 230V 50Hz with a 2 Amp rating is required for the electronic control unit NOTE The position of the Control Unit is important to provide access should adjustments be necessary and for maintenance It must be located in a dry area away from plumbing that could potentially leak b Installation of the electronic Control Unit must be completed prior to procee...

Страница 14: ...Revision 3 14 Product Manual ALB 01 03 05 Figure 4 Solenoid Control unit installation connection ...

Страница 15: ...ck hard set mastic must be applied around the panels to fill any gaps and between the panels and the bath rim and the walls Refer to section 5 2 for details on suitable anti pick products 5 5 Commissioning for use To commission the ALB bath 1 Fully open the water supply isolating taps Check the system for leaks 2 Operate the hot and cold water by pressing the piezo touch buttons Operate the water ...

Страница 16: ...ADA 120V AC 2Amp 60Hz for models WDCA100 and WDCA200 Power rating Maximum power rating 60 W Weight 1 0 Kg Dimensions 200mm W x 150mm H x 80mm D Enclosure IP Rating IP53 Regulatory compliance Complies with RoHS LVD 2014 35 EU and EMC 2014 30 EU directives Table 1 Technical specifications NOTE The minimum operating pressure quoted is the minimum that the water solenoid valves will operate at At this...

Страница 17: ... NOTE If a fault occurs with the unit you must set the isolator to the OFF position until the fault is repaired by a qualified engineer WARNING Risk of electric shock serious injury and death Only trained and qualified personnel should remove the cover of the electronic control box 2 Operate the cold and hot water nozzles by pressing the piezo touch buttons The piezo touch buttons do not have any ...

Страница 18: ...list table below Part Number Description WN4003 Water nozzle aerator insert RW9602 Rubber seal for WN4003 WF4002 Locking ring for WN4003 DL7523 Key to remove Tap head aerator nozzle ring FLAT TYPE KEY DL7539 Key to remove Tap head aerator nozzle ring CIRCULAR TYPE KEY Table 2 Spare Parts List 7 Related Documentation The ALB bath can be used with any of the following control units WDC100 For more i...

Страница 19: ...Revision 3 19 Product Manual ALB 01 03 05 Notes PAGE INTENTIONALLY LEFT BLANK ...

Страница 20: ...Revision 3 2 Wallgate Ltd Crow Lane Wilton Salisbury Wiltshire SP2 0HB England tel 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com ...

Отзывы: