Service and Maintenance
WX520 / WX520L / WX520T
Log Splitter
30
Figure 16 –
Grease points
1
1
2
2
9.4 Grease Points
Use a hand-held grease gun for all greasing. Pump one shot
of grease per fitting.
Look for this decal on your machine. It
indicates a grease point and the interval in
hours.
•
Wipe grease fitting with a clean cloth before greasing to
avoid injecting dirt and grit.
•
If fittings do not take grease, remove and clean them
thoroughly. Replace grease fittings as necessary.
Location
Every 40 hours of operation
or as required
1
Frame slide (apply a small amount of grease to the
slide).
Location
Every 100 hours of operation
or annually
2
Axle bearings
Содержание WX520