background image

Installation Instructions

The installation of the Wallbox should be undertaken by a qualified electrician in accordance 
with  the  applicable  standards  and  regulations.  Preferably  the  installation  should  be 
undertaken  by  a  Wallbox  trained  installer.  Local  regulations  on  electrical  installations,  fire 
prevention, and accidents as well as emergency exits implemented from installation must be 
taken into account.

Please contact an electrician or arrange installation at your premises with your local distributor.

PRECAUTIONS

Flammable, explosive, or combustible materials.
Chemicals or solvents.
Gas pipes or steam outlets.
Heat emitters such as radiators or batteries.
Areas prone to flooding, running water or humid environments.

Take special care when selecting the mounting surface. It must be able to adequately 
support the weight of the charger and withstand the mechanical forces associated to 
charger use.
The power supply connection must comply with the standards and regulations for cabling 
and building infrastructure.
The Wallbox charger must be permanently connected to the electrical earth of the 
installation.
Before installing or cleaning your Wallbox make sure that the power supply is switched off 
and there is no power in the system.

The charger must be installed in a su

ff

iciently ventilated location to ensure it remains cool. 

Always bear in mind the operating temperatures of the device.
It is recommended to avoid installation in areas where there is direct sunlight to prevent 
overheating and deterioration of the device.

Do not install your Wallbox charger near:

en

6

Electrical Protection

• The power supply line must be wired to an existing installation and be in

accordance with local regulations.

• The charger must be electrically protected by installing externally a Miniature

Circuit Breaker (MCB) and a Residual Current 

Circuit Breaker

 (

RCCB

)

MCB: maximum value according to the maximum output current of the load point.

 

RCCB

: According to local regulations, Type A or Type B.

Recommended protections, take also into account the local regulations

Содержание commander

Страница 1: ...MMANDER Installation guide Gu a de instalaci n Installationsanleitung Guide d installation Installatiegids Guida per I installazione Guia de instalac o Installasjonsveiledning Asennusopas Distributed...

Страница 2: ...this Installation Guide does not relieve the user of responsibility to follow all norms and standards or local regulations that may apply The Wallbox charger device has been designed developed and man...

Страница 3: ...not step on it or on the cable The cable should NOT be tightened under ANY CIRCUMSTANCES while connected to the vehicle Do not operate if physical defects such as cracking breakage corrosion or other...

Страница 4: ...C a 40 C 40 C a 70 C LVD2014 35 EU EMCD 2014 30 EU IEC61851 1 IEC61851 22 IEC62196 1 en 4 Cable length Connector type Commander 5 m 7 m optional 1 Type 1 SAE J1772 or Type 2 IEC 62196 2 Electrical sp...

Страница 5: ...Screws 4x 8mm Wall anchors 1x RutaSeal sealing 4x Plugs Components Wallbox Commander with charging cable I 1 Installation guide Mounting parts Drilling template I 2 Opening tool I 9 en 5 1 2 3 4 5 6...

Страница 6: ...ion must comply with the standards and regulations for cabling and building infrastructure The Wallbox charger must be permanently connected to the electrical earth of the installation Before installi...

Страница 7: ...tation you must observe the minimum distances recommended to other technical installations Mounting 1 OPENING THE DEVICE I 9 Step 1 1 Remove the screw on the bottom side I 5 1 Step 1 2 Carefully open...

Страница 8: ...45 V follow the next configuration steps Bi phase setup 2P From left to right L1 Current line N Current line Protective earth If network not IT The colours shown are not subject to international stand...

Страница 9: ...case of any doubt contact your sales agent POWER BOOST If your charger is going to be part of a Power Boost please be sure you have the instructions to perform this installation In case of any doubt c...

Страница 10: ...1 Italia 39 694804494 Nederland 31 202410845 Norge 47 51742000 Portugal 351 308809158 sterreich 43 720882116 Schweiz Suisse 41 435084675 Sverige 46 852503203 United Kingdom 44 2039097682 Limited warra...

Страница 11: ...12 I 1 I 2 250 150 250 150 I 4 I 6 TILA S HK VIRTA A 6 0 0 1 2 10 3 13 4 16 5 20 6 25 7 32 8 0 9 0 y I 3 EDIT FOR COMMANDER WBCM 0 2 4 0 001 B...

Страница 12: ...13 1 I 5 1 I 5 2 I 5 3 I 7 2 2 I 7 1 1 3...

Страница 13: ...I 7 4 I 7 3 I 8 I 9 OPENING TOOL IMAGE Distributed by e Mobility Division TransNet NZ Limited 78 Cryers Road East Tamaki Auckland 2013 NEW ZEALAND 64 9 274 3340 ev transnet co nz www evc co nz...