min. 300 mm
min. 1 m
WALLAS
en
Installation
Combustion gas connections
Location of the exhaust head
Location in the underframe
When selecting the location for installing the
4300
exhaust head, the internal layout
of the vehicle and routing of the combustion gas and intake air hoses should be
taken into account. Try to keep the hoses as short as possible. Also keep in mind
that the combustion gas hose becomes hot.
A free flow of air past the exhaust head must be ensured at all times. Install the
exhaust head on a straight surface, flush with the vehicle’s side line. Avoid corners
and cavities where wind pressure may disturb the unit’s operation. Also bear in
mind that when installed in the middle of the vehicle, the exhaust head will reduce
ground clearance the most.
The minimum distance of the exhaust head from the fuel tank’s filler hole is 400
mm (16”).
The front edge of the exhaust head must always be installed flush with the vehi
-
cle’s side line, in a slight downward inclination (at least 5°); the head must not be
under the vehicle. The minimum distance from the rear tyre of the vehicle is 0.3
metres, while the minimum distance from the front tyre is one metre. The exhaust
head must not be installed at the rear end of the vehicle.
A good place for the exhaust head
A possible place for the exhaust head
The exhaust head must not be installed here
DOOR
DOOR
reduces ground clearance
reduces ground clearance
reduces ground clearance
The minimum ground
clearance shall not be
exceeded.
Make sure that there is
open way to the point
of jack up.
D10341D