GB
Installation
Flush opening size is 280 x 448 mm.
Control panel (2), (88 x 42 mm), opening 62 x 38 mm.
– Control cable length 2 m.
The ventilation slot
at rear
must be left open and uncovered.
The cover list (3) is fastened on it’s place with a tape inside.
The stove requires for it’s ventilation to avoid overheating an air intake open-
ing of 100 cm
2
below the stove.
Template for exhaust head
“take through” drilling.
Use the exhaust head
base plate as template. The taking through deck must be carefully silicone
sealed.
The “through hull” board exhaust head type 1066
.
Exhaust tube no
1028
, Flexible, stainless quality, ø 31/28 mm, max length 5
meters. Taking through constructions must be ventilated, - not closed.
The fuel tank must always, under all circumstances lie below the stove bot-
tom level, secured so it can not tip or come loose.
The return fuel tube
must have continuos fall to fuel tank with no loops
upward. All extra length is cut away below the tank adapter. The end of the
return tube must reach the bottom nib.
Fuel tank adapter no 367204
Filter head, sinterbronze no
367402
Filter holder nut
Filter holder nut rubber ring
Filter shield washer ring
Fuel suction line, ø 5/2 mm, transparent, polyamid
Thread lock ring
Rubber sleeves to secure fuel lines
Take through plate
Gasket no
364001
Fuel steam lock
Shield spiral no
367001
hinders water intake by holding the suction
end free from tankbottom
Connect the power cord to the electronics card
1
3
4
5
2
6
7
8
9
10
11
12
21
22
23
24
25
26
27
28
29
30
13