- 17 -

Error Codes

Possible error codes are listed on the table below.

Combined
Code

Error message

Problem

Troubleshooting

10A06

Ignition failed

Ignition failed, maximum allowed
number of pump pulses

Check the fuel, check the fuel filter,
tighten all joints.

10A06

Ignition failed

Preheating failed, residual fuel burning
for too long

Try to start again, if same fault, contact
service.

1020B

Low voltage

Supply voltage is below minimum

Renew/charge the battery.

10001    

System error

Contact service

10003    

System error

Contact service

10201

System error

Unexpected flame-out

Check the fuel level, check the fuel filter.

20005

System error

Contact service

20A0207

System error

Water thermostat is missing water
temperature data

Contact service

20B0205

System error

Analog control (potentiometer) is
missing

Connect the controller, check contropanel
wiring.

203020A

Ignition failed

No fuel was detected, maximum
allowed number of pump pulses

Check the fuel, check the fuel filter,
tighten all joints.

2010204

Combustion fan

Burner fan is not working (no
tachometer signal)

Contact service

2020204

System error

Ventilation fan is not working (no
tachometer signal)

Contact service

2030204

System error

Fuel pump output short-circuit

Fuelpump wires are in shortcut, check the
wiring.

2030205

System error

Fuel pump not connected (no current
detected on output)

Fuel pump is missing, connect fuel pump
connector.

2040205

Water pump

Water pump is missing (no load on
output)

Connect the waterpump connector.

2050204

System error

Burner or ventilation fan power short-
circuit

Contact service

2060204

Glow plug

Glow plug short-circuit

Renew the glow plug.

2060205

Glow plug

Glow plug missing (no current detected
on output)

Renew the glow plug, check that the glow
plug connector is connected to the ECU.

Содержание 3008

Страница 1: ...Advanced Control Panel 3008...

Страница 2: ...Control Panel 3008 Installation 1 Control Panel Control Panel 3008 basic features 2 Control Panel Software update 10 Control Panel Wallas Remote application and Control Panel connection 11 Control Pan...

Страница 3: ...panel in place top down Remove the display protection tape Install the assemply plate Drill 12 mm hole for the cable Draw and check hole place before drilling it should not be visible when panel is o...

Страница 4: ...embly instructions from sales package and connected with the Wallas unit This manual refers to Control panel SW 1 2 75 and heater SW 1 6 64 Starting the heater for the first time Prior to starting the...

Страница 5: ...se the desired mode Press the Select Button Press and hold the Select Button down again for 3 seconds to start the heater safety feature Use Arrow Buttons to set the desired temperature and press the...

Страница 6: ...Heater power Operation modes Main Menu Bar Manual control mode heater power is manually controlled with 6 power levels 1 6 Thermo control mode set a target temperature C F heater controls the power l...

Страница 7: ...he burner flame has been ignited and the combustion has stabilized in about 5 min Heater will be fully operational about 10 minutes later Temperature Power setting In Thermo Control Mode move the sele...

Страница 8: ...heating at 6 blower speeds Choose Ventilation Mode prior to starting the device Use the Arrow Buttons to move the selection square to the Main Menu Bar and press the Select Button to activate it Use A...

Страница 9: ...screen Heater will re start heating again automatically if the cabin temperature falls 2 degrees C 3 6 F below the set target temperature Shut down Option 1 Quick shut down Press and hold the Select B...

Страница 10: ...nit serial number needed for customer service tech help Device Stats Check there is enough voltage to start the unit must have at least 10 V Check usage hours units must be serviced every 2000 hours 3...

Страница 11: ...9 Temp Unit select temperature unit Celcius Fahrenheit Connections clear all paired mobile phone devices Adjust combustion in high altitudes Heater operation can be optimized to different altitudes...

Страница 12: ...Spot name SSID is visible in application page and the status is Connected the heater is OFF before starting the update Updating may take up to 6 minutes depending on network and connection If new soft...

Страница 13: ...iring the app with the heater Mobile Device Advanced Control Panel Mobile Device Advanced Control Panel Turn the short range wireless connection on your mobile device for pairing the app with the cont...

Страница 14: ...ful Connection Denied will appear on the Control Panel Use Arrow Buttons to go to the Main Menu Bar and press the Select Button Go to the Settings and press the Select Button Choose Connections and pr...

Страница 15: ...art Stop Icon down for 2 seconds to start the heater Starting will appear on the screen Orange combustion light will light up when the burner flame has been ignated and the combustion has stabilized a...

Страница 16: ...ill re start heating again automatically if the cabin temperature falls 2 degrees 3 F below the set target temperature Press and hold the Start Stop Icon down for 2 seconds Stopping will appear and th...

Страница 17: ...top takes several minutes You can see when heater was last connected into internet and what is the heater state You can see some statistics of your heater Available graphs will vary depending of your...

Страница 18: ...de manually Remove WALLAS OP from your phones paired short range wireless connection devices list note there might be several OP pairings in mobile device list remove all and restart short range wirel...

Страница 19: ...s missing Connect the controller check contropanel wiring 203020A Ignition failed No fuel was detected maximum allowed number of pump pulses Check the fuel check the fuel filter tighten all joints 201...

Страница 20: ...r overheat Water temperature is too high Water is not circulate bleed the air out of the system check the waterpump 50001 System error CAN bus other errors Contact service 50006 System error CAN bus t...

Отзывы: