Advanced Control Panel 3008

Содержание 3008

Страница 1: ...Advanced Control Panel 3008...

Страница 2: ...Control Panel 3008 Installation 1 Control Panel Control Panel 3008 basic features 2 Control Panel Software update 10 Control Panel Wallas Remote application and Control Panel connection 11 Control Pan...

Страница 3: ...panel in place top down Remove the display protection tape Install the assemply plate Drill 12 mm hole for the cable Draw and check hole place before drilling it should not be visible when panel is o...

Страница 4: ...embly instructions from sales package and connected with the Wallas unit This manual refers to Control panel SW 1 2 75 and heater SW 1 6 64 Starting the heater for the first time Prior to starting the...

Страница 5: ...se the desired mode Press the Select Button Press and hold the Select Button down again for 3 seconds to start the heater safety feature Use Arrow Buttons to set the desired temperature and press the...

Страница 6: ...Heater power Operation modes Main Menu Bar Manual control mode heater power is manually controlled with 6 power levels 1 6 Thermo control mode set a target temperature C F heater controls the power l...

Страница 7: ...he burner flame has been ignited and the combustion has stabilized in about 5 min Heater will be fully operational about 10 minutes later Temperature Power setting In Thermo Control Mode move the sele...

Страница 8: ...heating at 6 blower speeds Choose Ventilation Mode prior to starting the device Use the Arrow Buttons to move the selection square to the Main Menu Bar and press the Select Button to activate it Use A...

Страница 9: ...screen Heater will re start heating again automatically if the cabin temperature falls 2 degrees C 3 6 F below the set target temperature Shut down Option 1 Quick shut down Press and hold the Select B...

Страница 10: ...nit serial number needed for customer service tech help Device Stats Check there is enough voltage to start the unit must have at least 10 V Check usage hours units must be serviced every 2000 hours 3...

Страница 11: ...9 Temp Unit select temperature unit Celcius Fahrenheit Connections clear all paired mobile phone devices Adjust combustion in high altitudes Heater operation can be optimized to different altitudes...

Страница 12: ...Spot name SSID is visible in application page and the status is Connected the heater is OFF before starting the update Updating may take up to 6 minutes depending on network and connection If new soft...

Страница 13: ...iring the app with the heater Mobile Device Advanced Control Panel Mobile Device Advanced Control Panel Turn the short range wireless connection on your mobile device for pairing the app with the cont...

Страница 14: ...ful Connection Denied will appear on the Control Panel Use Arrow Buttons to go to the Main Menu Bar and press the Select Button Go to the Settings and press the Select Button Choose Connections and pr...

Страница 15: ...art Stop Icon down for 2 seconds to start the heater Starting will appear on the screen Orange combustion light will light up when the burner flame has been ignated and the combustion has stabilized a...

Страница 16: ...ill re start heating again automatically if the cabin temperature falls 2 degrees 3 F below the set target temperature Press and hold the Start Stop Icon down for 2 seconds Stopping will appear and th...

Страница 17: ...top takes several minutes You can see when heater was last connected into internet and what is the heater state You can see some statistics of your heater Available graphs will vary depending of your...

Страница 18: ...de manually Remove WALLAS OP from your phones paired short range wireless connection devices list note there might be several OP pairings in mobile device list remove all and restart short range wirel...

Страница 19: ...s missing Connect the controller check contropanel wiring 203020A Ignition failed No fuel was detected maximum allowed number of pump pulses Check the fuel check the fuel filter tighten all joints 201...

Страница 20: ...r overheat Water temperature is too high Water is not circulate bleed the air out of the system check the waterpump 50001 System error CAN bus other errors Contact service 50006 System error CAN bus t...