Technical information
Technical information
Heater operation
Wallas heaters
26CC
and
40CC
have been designed especially for use in holiday
cottages.
Light furnace oil, diesel oil or paraffin can be used to fuel the device. The heater is
fed with fuel from a separate tank, which is positioned below the heater. The heater
is powered by a 12-volt battery, which can be recharged, for example, by a solar
cell, wind generator or a mains power adapter.
The combustion air is fed in from outside the device and its circulation is complete-
ly enclosed, and balanced with the flue-gas exhaust head, which eliminates the
effect of wind pressure on the combustion.
The heater’s evaporation burner is activated automatically when the device is
started. The glow plug in the burner ignites the fuel that has been pumped into the
burner. The glow time is fixed: it starts and ends automatically.
The heat sensor, in the heater, detects the flame’s heat and lights the red LED to
signal that the device has started.
All functions are controlled electronically. The fuel pump and combustion air blower
are fully stabilised against voltage fluctuations, which ensures clean combustion,
regardless of changes in the battery voltage.
The heater is equipped with built-in overheat protection, which cuts the fuel feed if
the device overheats.
When the heater is switched off, it cools down automatically. The cooling function
ventilates the burner, and discharges the flue-gases generated during the switch-
off, to the outside of the cottage.
Fuel
Operating voltage
Consumption
Heating power
Power consumption
Measurements
Weight
Max. permissible length of the flue
gas pipe
Max. permissible length of the fuel
hose
Heating area
Suitable flue gas lead-throughs
Accessories
Connections
Power adjustment
Start-up
Light furnace oil / diesel oil (cold resistance grade according
to conditions of use) or paraffin
0,2...0,4 A (when ignited ca. 4,5 min. 8 A)
3 m, (6 m insulated)
4031
Base housing
4206
Weekly timer
4430
Remote controller
Remote controller
Room thermostat or manual power control
Manually with a switch or with the automatic weekly timer
(accessory) or remote controller (accessory)
ca. 18,5 kg
ca. 25,0 kg
ca. 40...60 m
2
ca. 60...90 m
2
en
26CC / 40CC
D80151
- 39 -
12 V DC
0,09...0,26 l/h
900...2600 W
730x340x200 mm
6 m
4004
26CC
40CC
730x440x240 mm
1600...4000 W
0,16...0,4 l/h
490525C