FoldSmart™ Installation and Maintenance Manual
Revision 1 - MAY 2023
161
TECHNICAL SPECIFICATIONS
Technical Specifications
Model
FoldSmart™
Solar
FoldSmart XTS
Gate Specs
Imperial Measurement
(Wallace Equipment Standard)
For Reference Only:
International System of Units (SI)
Approximate Equivalents
HEIGHT
MIN Width
MAX Width
HEIGHT
MIN Width
MAX Width
6 ft
12 ft
30 ft
1.83 m
3.66 m
9,14 m
8 ft
12 ft
26 ft
2.4 m
3.66 m
7.92 m
10 ft
12 ft
20 ft
3.05 m
3.66 m
6.10 m
The above specifications take gate weight capacities into account.
Open/Close Time
Open/Close time set independently. Standard 8 seconds, adjustable up to 15 seconds.
Duty Cycle
Continuous
Drive
Electromechanical
Horsepower
1/2 hp
UPS Battery Backup
Cycles*
Field configurable to fail open or secure when batteries deplete. Standard battery backup gate
cycles: Two 12V 8Ah batteries. Up to 300 cycles after AC power loss. Extended battery backup
gate cycles: Two 12V 50Ah batteries. Up to 1,200 cycles after AC power loss.
Temperature Rating
-13
°
to 158
°
F (-25
°
to 70
°
C) (rating to -40
° F/-40° C with optional cold weather kit)
Operating Voltage
24VDC
Input Voltage
115V or 208-230V, 50/60Hz Solar: 24 VDC solar panels
Accessory Power
12VDC and 24VDC 1A each
Included Accessories
EMX IRB-MON photo eye set (or 2 optional) and two 8Ah batteries for backup power
Communication
USB or RS-232, RS-485, Ethernet/fiber using optional HyNet™ Gateway accessory
User Controls
SmartDC Controller with 70+ configurable settings. 32 character LCD display and 5 tact buttons
or a PC using S.T.A.R.T. software.
Relays
Two configurable user relays: 30VDC, 3A solid state and 250VAC, 10A electromechanical;
Optional Hy8Relay™ for 8 additional relay outputs
Finish
Hot dipped galvanized, optional powder coat finish, NEMA3R control cabinet
ETL Listed (UL 325)
Usage Class I, II, III, IV
Cycle Tested
500,000 cycles
Warranty
3 year standard
*
The actual number of gate cycles available from battery depends upon gate resistance to travel, cycle length, battery size,
state of charge and health, ambient temperature, accessory power draw and frequency of gate cycles during power outage.
To enable fully automatic operation, all SWING gate operators require a minimum of ONE monitored external entrapment
protection sensor to protect entrapment zones in either the open or close direction of travel. However, an additional monitored
sensor is required if there is a risk of entrapment in both directions of gate travel. Visit
https://support.hysecurity.com/hc/en-us/
categories/360003177593-Safety
for more information on UL 325 standards and gate safety.
Содержание FOLDSMART
Страница 35: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 35 FOLDSMART GATE INSTALLATION ...
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 37: ...FoldSmart Installation and Maintenance Manual Revision 1 MAY 2023 37 FOLDSMART GATE INSTALLATION ...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Страница 146: ......
Страница 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 160: ......
Страница 162: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com ...