114
wallaceperimetersecurity.com
Phone: 866.300.1110
INSTALLER MENU FUNCTIONS
Table 6. SmartDC Controller - Installer Menu Functions
Ref.
No�
Installer Menu
Setting Options
(
Bold
= Factory Settings)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
41
ILD 0 (RUN MODE)
IN OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY5A/HY5B/HY5B 2.0 Inside
Obstruction Loop detector. If an HY5B
is used, additional settings of 4-8 are
available:
4 = Show Sensitivity
5 = Set Sensitivity
6 = Show Inductance
7 = Show Loop Health
8 = Set Presence
HY5A/HY5B/
HY5B 2.0
42
OLD 0 (RUN MODE)
OUT OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY5A/HY5B/HY5B 2.0
Outside Obstruction Loop detector. If an
HY5B is used, additional settings of 4-8 are
available:
4 = Show Sensitivity
5 = Set Sensitivity
6 = Show Inductance
7 = Show Loop Health
8 = Set Presence
HY5A/HY5B/
HY5B 2.0
43
CLD 0 (RUN MODE)
CENTER LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY5A/HY5B/HY5B 2.0 Center
Loop (Shadow) detector. If an HY5B
is used, additional settings of 4-8 are
available:
4 = Show Sensitivity
5 = Set Sensitivity
6 = Show Inductance
7 = Show Loop Health
8 = Set Presence
Note:
Center loop has no gate control
function in a slide gate
. However, the
input may be used as an arming loop
when used in conjunction with Relay
function #22.
HY5A/HY5B/
HY5B 2.0
Содержание ALPHA
Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 40: ...40 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 42: ...42 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 44: ...44 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...
Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 50: ...50 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 54: ...54 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 56: ...56 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...
Страница 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...
Страница 168: ......
Страница 169: ...Figure 48 Schematic for Kinetic DCS 15 Kinetic 1S and Kinetic DCS 10F Kinetic 2S Solar Operator s...
Страница 170: ......
Страница 180: ......
Страница 182: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...