background image

CONTENTS OF THE PACKING CASE 
 

1 x Machine body complete 
2 x Handle bars 
1 x Spray Boom assembly 
 
 
 1 x Plastic bag containing: 
 
 4 x Handle bolts, wingnuts and washers 
  2 x Cable Clamps 
 1 x Instruction manual and Warranty 
 

 
 
 
 
ASSEMBLY INSTRUCTIONS 
 

The RAMBLER sprayer has been factory 
tested prior to packing and only requires 
the handles and the spray boom assembly 
to be fitted. 
Fit the handlebars into position using the 
nuts, bolts and washers from the fixing bag. 
The boom assembly can be fitted to the 
main frame in two positions. The upper 
position should be suitable for most 
purposes. Take the boom assembly and 
attach it to the main frame by using the 
clamps. The boom is marked showing its 
centre position, and this should be carefully 
aligned into the centre of the fixing clamp. 
BEFORE tightening the clamp the machine 
should be lifted into its normal working 
position and the boom nozzles checked to 
ensure they are parallel to the ground. 
Adjust the boom position and rotation as 
necessary, re-check, then tighten the clamp 
fixings. Attach the inlet wing nut to the 
boom inlet housing. The machine is now 
ready for testing. 
 

TESTING 
 

A trial run should be carried out on a dry 
concrete surface to check that the nozzles 
are in alignment. This should be carried out 
using clean water to ensure everything is in 
working order. 
Half  fill the container with cold water, 
replace the filler cap & filter and move off at 
a steady working place similar to the speed 
of mowing.  
 
This will prime the pump mechanism and 
water will spray from the nozzles, showing 
that all air has been bled from the system. 
If an airlock remains in the system, unscrew 
the two diaphragm check valve caps and 

push the machine until water flows through 
the system. Tighten the two caps and then 
push. The machine will then start to spray. 
DO NOT over tighten the diaphragm caps. 
They are fitted in order to clear the spray 
system of air & other small blockages. 
 
 

 
OPERATING INSTRUCTIONS 
 

When filling the machine, add sufficient 
liquid treatment to cover the area needing 
treatment or a pro-rata amount if only part 
filling. Pay careful attention to which colour 
nozzle is fitted at the time of spraying to 
avoid any over or under application of 
chemical. Always follow the chemical 
manufacturers instructions relating to the 
specific area. In many instances dilution 
rates of chemicals are not critical, but in 
some cases where a greater volume of 
water is needed, then two x half strength 
applications are recommended, spraying 
where possible in a chequer board fashion 
in North to South and East to West 
directions. 
 

SPRAY WIDTH 

 
The RAMBLER has a spray width of 40 
inches (1016mm). In common with all 
Walkover sprayers, the spray pattern tails 
off on the extreme edge of the treated 
swath which is compensated for when 
treating the return track. You must therefore 
always ensure your return track is 40” 
(1016mm) from the datum point of your 
previous pass to achieve correct coverage. 
A set of red nozzles are provided with the 
machine. Nozzles giving alternative 
coverage areas for the 25 litre (5.5 gallons) 
loading as follows: 
 

(a)  With standard nozzle fitted, Red 

ANDT 2.0, one full tank covers 825 
sq. metres (1000 sq. yards) 
equivalent to 298.6 litres/hectare 
(26.6 gallons/acre) 

(b)  Alternative nozzle, Grey

 

TF VP 3 

delivers to one full tank 500 sq. 
metres (670 sq. yards) equivalent 
to 449 litres/ hectare (40 
gallons/acre) 

N.B

 The coverage areas for each nozzle 

may vary plus or minus 5% depending on 
the speed of operation and variations of the 
terrain. 
 

 

Содержание Fieldmaster

Страница 1: ...Rambler Sprayer Handbook Operating Instructions Parts List www walkoversprayers com sales walkoversprayers com Tel 0845 521 1209 Fax 01269 844636 ...

Страница 2: ...phragm check valve caps and push the machine until water flows through the system Tighten the two caps and then push The machine will then start to spray DO NOT over tighten the diaphragm caps They are fitted in order to clear the spray system of air other small blockages OPERATING INSTRUCTIONS When filling the machine add sufficient liquid treatment to cover the area needing treatment or a pro ra...

Страница 3: ...the pump mechanism that could granulate and score the interior surfaces This could impair the performance of your machine Where temperatures below zero degrees are likely to be experienced ensure that all liquid has been drained from the machine by removing the hose from the pump This elbow is a snap fit and pulls out quite easily at a slight angle Rotate the drive wheel to empty the pump and pipe...

Страница 4: ... substance which can crystallise if left in the machine after use This solidifies within the pump and nozzles and can in extreme instances completely destroy the pump mechanism Many propriety brands of garden and horticultural chemical are sold in the form of Soluble powder or Crystals The RAMBLER sprayer will satisfactorily apply these chemicals always providing that the crystals or powder are co...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ...1 W1117 Rectangular Clamp 31 1 W1573 ID x 22 Long Durapipe PP Class E 47335 32 1 W2057 Pump Hex Drive 33 1 W1069 Outlet Securing Clip 34 1 W1279 BSP Cap and Liner 35 1 W1276 Elbow Nut 11 16 NPT x Hose Tail 36 1 W1415 ID x x 27 Long Tube Tap to Tank 37 1 W1166 BSP x Hose Tail Elbow 38 1 W1628 BSP Ball Valve 39 1 W1121 BSP x Hose Tail 40 1 W1414 ID x x 24 Long Tube Tap to Tee 41 1 W1125 Equal Tee 42...

Страница 10: ... gallons 0 22 1 sq foot 144 sq inches 0 0929 sq metres 1 sq yard 9 sq feet 0 8361 sq metres 1 Acre 4840 sq yards 4046 9 sq metres 1 Hectare 10 000 sq metres 11 960 sq metres 1 Gallon 8 Pints 4 5461 Litres USA Fluid Measurements 1 US Pint 16 fl Oz 0 8327 Imp Pints 0 4732 litres 1 US Gallon 0 8327 Imp Gallons 3 7853 Litres User Notes Date Purchased Serial Number ALWAYS Flush thoroughy after use add ...

Страница 11: ......

Страница 12: ...move nozzle cap by turning the cap one half turn anti clockwise Clean nozzle or replace Replace cap and try machine again 3 Blocked tubes or tank Remove diaphragm control valves and nozzle caps Disconnect a convenient tube joint Using the water pressure from a garden hose force blockage through the system increasing the water pressure as necessary Reassemble when blockage is clear 4 Drop in pressu...

Страница 13: ...se nozzle cap by turning the cap one half turn anti clockwise realign nozzle and retighten the cap Mixed nozzles You may have different nozzles fitted Refit matching nozzles as required Machines fitted with an on off tap 6 Machine still sprays when the tap is turned off The return tube to the tank is blocked Remove and flush with garden hose to clear blockage If the unit is being towed the towing ...

Страница 14: ...r item manufactured by Walkover that is found to be defective within 12 months from the date of purchase or in the case of a machine used for hire purposes 45 days Walkover undertake to replace the faulty component s free of charge either directly or through authorised dealers This does not affect your statutory rights Walkover operate a policy of continuous improvement and reserve the right to al...

Отзывы: