INDICATING LAMPS, I.R. REMOTE, and LOCAL CONTROL
ADANGER
Do Not Attempt To Lift a Load While Alarm Is
Sounding Or Red "Danger" Indicator Is On.
INDICATOR LIGHT DISPLAY DURING LIFT
When the magnet is on a load and the "LIFT" button on the Front Panel or I.R. remote is pressed, the
red "DANGER" indicator will light and the alarm will sound. The alarm may continue for a few sec
onds, until the magnetic energy builds up to the proper level needed for lifting.
NEVER BEGIN TO
LIFT A LOAD WHILE ALARM IS SOUNDING OR WHEN THE RED DANGER INDICATOR IS ON.
If
the red DANGER indicator remains on and the alarm continues to sound,
DO NOT USE THE MAG
NET.
See Troubleshooting page 21 section B for more information.
The panel indicators indicate the battery's charge level while using the magnet. When the magnet is
turned on, the lamps indicate the voltage level of the battery. When the four green lamps go out, the
battery charge is low and it should be recharged before doing any further lifting.
After a complete battery charge (as indicated by a green Battery indicator), ALL the charge level
lamps should light when the "LIFT" button on the Front Panel or I.R. remote is pressed. If, however,
the last green indicator turns off shortly after the magnet has been turned on, this could indicate the
battery's inability to retain the charge level. See Troubleshooting page 21 section C for more informa
tion.
ADANGER
Observe the battery charge level indicators frequently during each lift. If the red
DANGER indicator goes on and/or the alarm sounds during a lift, set the load down
immediately.
INDICATOR DISPLAY DURING CHARGING
With the magnet off and the power cord plugged into a 115 VAC source, the red "BATTERY" indica
tor light should turn on within 10 seconds indicating the battery is being charged. When the battery is
nearly fully charged, the "BATTERY" indicator will alternate between red and green. Once the battery
is fully charged, the charger maintains a float charge on the battery to maintain a full charge. This is
indicated by the "BATTERY" indicator staying lit green. The battery is now fully charged and ready for
use. Using the magnet prior to the battery being fully charged will reduce the safe operating time of
the magnet.
If no lamps come on after the charger is initially plugged in, unplug the unit and see Trouble
shooting page 22 Sections H & I.
When the green "BATTERY" indicator turns on, the charger may be left plugged in if desired. A con
stant float charge is maintained on the battery and will keep the battery fully charged.