17
Section 4:
Mechanical Installation
Re configuration of the inlet / outlet ports
PD0046 – PD0360 models
•
Dryer can be reconfigured to interchange position of
inlet and outlet ports as per figure 4.8.
•
PRODRY has two inlet ports (A and B) and two outlet
ports (C and D). Either (A or B) can be used for inlet
and (C or D) for outlet. Make sure the un-used ports are
blanked off with provided pressure plugs.
Figure 4.8: Inlet/outlet ports
A
C
B
D
Any of the two outlet ports can be used on
occasion. Please ensure flow at outlet should not
exceed specification. Please adhere to regional
regulations.
It is strongly advised to connect a non-return
valve to the outlet port of the dryer.
Only use one inlet port at any one time
Ensure original seals are in place.
Check dryer is leak-free prior to operation.
Tools required
• Adjustable spanner
• Ratchet with 17mm Hexagonal connection
(PD0046 - PD0180)
• Ratchet with 1” Hexagonal connection
(PD0220 - PD0360)