background image

I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l  

Gas Salamander 

SN8200G 

SNB8200G 

SN8200GB 

SNB8200GB 

 

 

 

231921-16 

 

For use in GB & IE 

Содержание SNB8200G

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Salamander SN8200G SNB8200G SN8200GB SNB8200GB 231921 16 For use in GB IE ...

Страница 2: ...800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 ...

Страница 3: ...nsions Internal Dimensions Cooking Area Weight Installation Requirements Unpacking Location Clearances Wall Mounting to non combustible wall only Gas Connection Commissioning Operation Guide Description of Controls Lighting Main Burners Racking System Cooking Recommendations General Racking Stainless Steel Surfaces Vitreous Enamel Surfaces Trough Tray Conversion Procedure Gas Specifications ...

Страница 4: ...adapting appliance to conditions for use in that country GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMAB...

Страница 5: ...rom flat to angled position by partial removal of rack Rack height must be fully removed for repositioning of rack height setting Branding Plate is available as an accessory item Refer to Replacement Parts List SN8200GB Rack supports have 4 fixed height positions offering flat and angled rack positioning Rack can be changed from flat to angled position by partial removal of rack Rack height must b...

Страница 6: ...minal 8 8 kW 8 8 kW Reduced 3 6 kW 2 6 kW Gas Rate Nominal 0 84 m3 hr 0 63 kg hr Reduced 0 34 m3 hr 0 19 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 10 mbar 26 mbar Gas Connection 1 2 BSP Male Input Rating N H G C 31 5 MJ hr 31 5 MJ hr Supply Pressure 1 13 3 4 kPa 2 75 4 5 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Connection BSP Male Input Rating N H G C 31 5 MJ hr 31 ...

Страница 7: ...ied Refer to Gas Conversion and Specifications section of this manual for further details Gas supply connection point is located 25mm in from the rear of the appliance 130mm from the right hand side and is entered from beneath appliance Connection is BSP male Input Rating N H G C 31 5 MJ hr 31 5 MJ hr Supply Pressure 2 75 4 50 kPa 2 75 4 50 kPa Burner Operating Pressure 2 55 kPa 2 55 kPa Gas Conne...

Страница 8: ...6 Width 685mm Height 230mm at front Depth 330mm Rack 610mm x 310mm Branding Plate Accessory 610mm x 310mm 41kg without Branding Plate or Racking System 900 ...

Страница 9: ...y damage immediately to carrier and distributor Report any deficiencies to distributor who supplied appliance Check available gas supply is correct to that shown on rating plate located on front bottom corner of right hand side panel Check the following parts have been supplied with appliance 1 Installation must allow for a sufficient flow of fresh air for combustion air supply 2 Installation must...

Страница 10: ...lose proximity to this appliance We recommend a clearance of 100mm on either side of appliance to allow access to side panels for servicing purposes Using wall mounting accessories provided with this appliance Left Right Hand side 100mm 25mm Rear 50mm 30mm ...

Страница 11: ...orners of unit Leave them unscrewed by approximately 5mm 3 Fit two adjusting screws bolts into nutserts at bottom rear corners of unit These should protrude approximately 30mm from rear of Salamander 4 Lift Salamander onto wall bracket lining up black plastic spacers on salamander with mounting notches in bracket 5 Lower Salamander onto mounting bracket 6 Tighten black spacers securely and adjust ...

Страница 12: ...ble to give maximum supply volume 3 Fit gas regulator supplied into gas supply line as close to appliance as possible Refer to Specifications section for gas supply location dimensions NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is converted to correct gas type that appliance will ...

Страница 13: ...the operator has been instructed in areas of correct lighting operation and shutdown procedure for appliance 2 This manual must be kept by owner for future reference and a record of Date of Purchase Date of Installation and Serial Number of Unit recorded and kept w ith this manual These de tails can be found on Rating Plate attached to R H side panel refer to Gas Connection section NOTE If it is n...

Страница 14: ...dividual heat controls for left and right sides Select desired heat level and allow a few minutes for elements to heat up Waldorf salamanders provide two independently controlled heat zones High speed grilling is provided by two infrared gas burners in ceiling of grilling compartment Left hand and right hand gas control knobs operate the left side and right side burners respectively independently ...

Страница 15: ...5kg 1 The SN8200G Salamander has been designed to give a good evenness of heat across rack area so toasting cheese melting and grilling should be relatively even wherever food is placed 2 The HIGH position is recommended for most grilling cheese melting functions and LOW for reduced heat 3 For cooking food through rather than just surface browning rack position three and four from the top is recom...

Страница 16: ...Branding Plate from rack if fitted 3 Slide rack out of side racks and remove from unit 4 Remove left and right hand side racks from unit by removing single securing screw from each of side racks 5 Withdraw left and right hand side racks from unit 6 Refit racking in reverse order once cleaning has been completed Clean with detergent Baked on deposits or discolouration may require a good quality sta...

Страница 17: ...gas tap spindles by pulling knobs away from control panel b Remove drip tray from appliance c Remove two screws on underside of control panel securing control panel to hob d Remove control panel from front of appliance e Remove 2 screws holding shaft plate to gas control body and remove control shaft and plate See Fig 9 Note orientation of shaft for correct re assembly f Using needle nose pliers o...

Страница 18: ...easing knob before thermocouple has heated Main Burner flame too small Gas pressure too low Partially blocked main injector Thermocouple faulty Hold knob in for at least 20 seconds following ignition of main burner Call service provider Call service provider Main burners will not light No gas supply Incorrect supply pressure Blocked main injector Faulty gas control Ensure gas isolation valve is tu...

Страница 19: ...o side access panels Main burner injectors 2 Remove main burner injectors and replace with correct size injectors as shown in Gas Specifications tables at rear of this section 1 Remove the following Gas control knobs from front of unit Two front control panels 2 Light main burners and check flame size on Low position Adjust burner gas control valve low fire adjustment screw as shown in Gas Specifi...

Страница 20: ...ed 5 Screw cap nut back onto regulator On completion of the gas conversion replace the gas type labels located at Rear of the appliance above the gas connection point Beside the rating plate Before leaving installation 1 Check all gas connections for leaking using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of the appliance as shown in the Installation Section of...

Страница 21: ...2 turns out c c w turn out c c w Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 10 mbar 26 mbar Gas Regulator Cap Screw Main Burner Injectors Ø 1 85mm Ø 1 15mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Supply Pressure 1 13 3 4 kPa 2 75 4 5 kPa Burner Operating Pressure 1 0 kPa 2 55 kPa Gas Regulator Cap Screw Main Burner Injectors Ø 1 85mm Ø 1 15mm Low ...

Страница 22: ...o Gas Conversion and Specifications section of this manual for further details Main Burner Injectors Ø 1 85mm Ø 3 50mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out ccw 4 turns out ccw Supply Pressure 1 13 3 40 kPa 0 76 1 50 kPa Burner Operating Pressure 1 00 kPa 0 63 kPa Gas Regulator Cap Screw Adjustable Regulator Adjust to the Burner Operating Pressure Main Burner Injectors Ø 1 15mm Ø ...

Страница 23: ...ne 1 10mm 032350 Main Injector Town Gas 3 50mm 019574 Low Fire Screw Nat Gas LPG Town Gas 1 00mm 019214K Burner Kit 026123 Burner Guard 232067 Thermocouple 231536 Ignition Electrode Non UK Models Only 227508 Piezo Ignitor Non UK Models Only General 026096 Wall Mounting Bracket 017963 Rack 013395 Rack Handle 026093 Side Rack 227961 Screw Side Rack 227950 Trough Tray Accessories Optional 013418 Bran...

Страница 24: ......