Cleaning and Maintenance

 

 
NOTE: It is imperative that trivet supports are correctly  

re-fitted to appliance to ensure that trivets locate 
correctly and sit flush and level.  NOTE that trivet 
support front end side rail profiles are different at 
either side (Refer to Fig 6) and only one of side rails 
seat into cut-out in range, whereas rear end of trivet 
support side rail profiles are same and have 2 
locating cut-outs. 

 

b.  Refit burner bowl onto manifolds protruding through 

splash guards, taking care not to damage thermocouple 

(and pilot tube - PF Option) which is close to manifold. 

 

NOTE:  Burner bowl (cast item) has 2 locating holes drilled into base flange (See Fig 7) these are to 

locate burner bowl onto cap screw on gas manifold when re-fitting burner bowl onto gas 
manifold (Refer to Fig 8 {F-Option} and Fig 9 {PF-Option}). 

 

c.  Refit burner caps (cast brass) onto burner bowls already fitted to manifold.  Burner cap is a loose 

fit into burner bowl. 

d.  Refit trivets to cook top, taking note that trivets are manufactured with a lip on one edge, lip 

must always be fitted to outer edge (front and back) of range.  (See Fig 10). 

e.  Refit grease / spill tray(s) to range. 

 

Oven Interior 

a.  Do not use wire brushes, steel wool or other abrasive materials to clean oven interior. 
b.  Clean oven regularly with a good quality domestic oven cleaner. 
c.  Weekly, remove and clean any built up of grease etc. from oven racks and bottom spill cover. 
d.  Dry oven thoroughly with a dry cloth and polish with a soft dry cloth. 

 

Periodic Maintenance 

NOTE:  All maintenance operations should only be carried out by a qualified service person. 

 

To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts 

should be checked and adjusted periodically by a qualified service person.  If any small faults occur, have 

them attended to promptly.  Don't wait until they cause a complete breakdown.  It is recommended that 

the appliance is serviced every 6 months. 

 

Gas Control Valve Re-Greasing 

Gas control valve should be dismantled and greased every 6 months 

to ensure correct operation. 

 

To carry out this operation;- 

a.  Remove gas control knobs from gas tap spindles by pulling 

knobs away from control panel. 

b.  Remove drip tray from appliance. 
c.  Remove two screws on underside of control panel, securing 

control panel to hob. 

d.  Remove control panel from front of appliance. 

e.  Remove 2 screws holding shaft plate to gas control 

body and remove control shaft and plate.  

(See Fig 11).  

Note orientation of shaft for re-assembly. 

f.  Using needle nose pliers or similar, pull out gas control 

spindle, again noting its orientation. 

g.  Apply a suitable high temperature gas cock grease or 

lubricant such as ROCOL - A.S.P (Anti scuffing paste) / 

Dry Moly Paste to outside of spindle.  

(See Fig 12).

 

h.  Replace spindle and re-assemble gas control in reverse order. 
i.  Refit the control panel to the appliance and secure with 2 screws. 

j.  Refit knobs to gas control valve spindles. 

Spindle 

Fig 9 

Notice Lip on 
Trivet Edge 

Fig 10 

Two Screws 

Fig 11 

Fig 12 

Содержание RN8510G

Страница 1: ... l l a t i o n a n d O p e r a t i o n M a n u a l Series RN8510G RN8610G RN8810G Gas Range Static Oven Date Purchased Serial Number Dealer Service Provider 228681 13 RNL8510G RNL8610G RNL8810G For use in GB IE DK ...

Страница 2: ...ares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales t...

Страница 3: ...allation 8 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 11 Operation Guide Description of Controls Open Burners Griddle Lighting the Oven Pilot Burner Lighting the Oven Main Burner Turning the Oven to Stand By Pilot ON Only Oven Shut Down Cleaning and Maintenance 15 General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance...

Страница 4: ...OT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appliance is for...

Страница 5: ... RN 1 8819G 2 Gas Range Static Oven 2 Open Burners 900mm Griddle Storage Cabinet NOTE 1 Back Options Standard Models L Low Back Models 2 Open Burner Options F With Flame Failure Protection PF With Pilot and Flame Failure Protection General A heavy duty general purpose gas range created for compact modular kitchens It has a high option Cook Top Griddle arrangement and is available on industrial adj...

Страница 6: ... G20 Propane G31 Open Burner each Griddle each 300mm section Oven Open Burner each Griddle each 300mm section Oven Heat Input nett Nominal 6 5 kW 5 5 kW 8 0 kW 6 5 kW 5 5 kW 8 0 kW Reduced 1 75 kW 1 85 kW 2 4 kW 1 75 kW 1 95 kW 2 4 kW Gas Rate nett Nominal 0 69 m3 hr 0 58 m3 hr 0 85 m3 hr 0 51 kg hr 0 43 kg hr 0 62 kg hr Reduced 0 19 m3 hr 0 20 m3 hr 0 25 m3 hr 0 14 kg hr 0 15 kg hr 0 19 kg hr Sup...

Страница 7: ...5 Dimensions RN L 8510G Cook Top Options RN L 8510G RN L 8513G ...

Страница 8: ...6 Dimensions RN L 8610G Cook Top Options RN L 8610G RN L 8613G RN L 8616G RN L 8619G ...

Страница 9: ...7 Dimensions RN L 8810G Cook Top Options RN L 8810G RN L 8813G RN L 8816G RN L 8819G ...

Страница 10: ...adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distributor who supplied the applianc...

Страница 11: ...s Type the appliance has been supplied for is shown on coloured stickers located above gas connection point and on rating plate Check this is correct for gas supply appliance is being installed for Gas conversion procedure is shown in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure adequate supply pressure exist...

Страница 12: ...e 10 Verify operating pressure remains correct Commissioning 1 Before leaving new installation a Check following functions in accordance with operating instructions specified in Operation section of this manual Lighting the Griddle Lighting the Open Burners F Flame Failure Option Lighting the Open Burners PF Pilot and Flame Failure Option Check the Low Fire burner operation Light the Oven Pilot an...

Страница 13: ...ning the Oven to Stand By Mode Oven Shut Down Description of Controls Griddle Option Burner Control OFF Position PILOT Burner HIGH Flame LOW Flame Gas Control Knobs Piezo Igniter Griddles Only Piezo Igniter Oven Oven Option OFF Position PILOT Burner Temperature Graduations 100 C to 290 C Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burner Front Burner Indicators are located above the ...

Страница 14: ...ned ON OFF without having to manually re light burner each time that it is turned ON as burner will automatically light itself off pilot burner Flame Failure Protection is incorporated for each burner by way of a thermo electric system which will shut off gas supply to that burner in event that burner goes out so that un burnt gas is not expelled a Select burner required depress and turn correspon...

Страница 15: ...h is incorporated by way of a thermo electric system for the main burner Flame failure protection will shut off gas supply to burner in the event that pilot burner goes out so that un burnt gas is not expelled This is an important safety feature which is slowly becoming law throughout the world 1 Open oven door Partially depress thermostat control knob whilst turning anti clockwise to Pilot positi...

Страница 16: ...amaged 1 To turn Off oven completely partially depress thermostat control knob whilst turning clockwise to O Off position pilot burner will extinguish DO NOT fully depress Thermostat Control Knob whilst trying to rotate clockwise to Off position as Knob and Gas Valve will be damaged Control Knob in Main Burner Operating Position Rotate Knob Anti Clockwise to Operating Temperature Control Knob in P...

Страница 17: ...detergent or cleaning material has been completely removed after each cleaning Appliance should be switched On briefly to ensure griddle plates become dry Oil or grease should be spread over griddle surface in order to form a thin protective greasy film To keep your range clean and operating at peak efficiency follow procedures shown below After Each Use 1 Clean griddle with a scraper tool to remo...

Страница 18: ...ce is cold and rub in direction of grain c It should not be necessary to remove splash guards covering burner manifolds for cleaning purposes These can be cleaned in situ d Remove grease tray and clean with a mild anti bacterial detergent and hot water solution using a soft bristled brush Clean control panel with a damp cloth moistened with a solution of mild detergent and water e Dry the grease t...

Страница 19: ...ean interior and exterior surfaces of range with hot water a mild detergent solution and a soft scrubbing brush Note that gas control knobs are a push fit onto gas control valve spindles and can be removed to allow cleaning of front control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when appliance is c...

Страница 20: ...pill cover d Dry oven thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NOTE All maintenance operations should only be carried out by a qualified service person To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person If any small faults occur hav...

Страница 21: ...Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Electromagnet in rear of gas control unit is faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or replace pilot injector Tighten thermocouple connection Check thermo couple is producing between 20 30mV Inspect and replace if not in good wor...

Страница 22: ...pports pilot shields PF options only splash guards 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section For F Options Only Unscrew and remove main injectors For PF Options Only Unscrew and remove main injectors and pilot injectors 3 Refit the following Splash guards pilot shields PF options only Trivet supports trivets burner caps ...

Страница 23: ...replace with correct size injectors as shown in Gas Specifications Tables at end of this section 4 Refit the following Re connect pilot supply tube to pilot burner Re connect piezo igniter to mounting bracket Refit main burner gas control heat shield and griddle plate to cooktop 5 Re light main burners and check flame size on Low flame position Adjust low fire adjustment screw on open burner gas c...

Страница 24: ...unting bracket Refit main burner and sole plate s 5 To Replace the low fire screw in the gas valve Remove the oven control panel Remove low fire screw from gas valve and replace with correct size low fire screw as shown in Gas Specifications Tables at end of this section NOTE The Low Fire Screw should be sealed with coloured paint on completion of low fire adjustment Refit the oven control panel G...

Страница 25: ...s DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES Warning Natural Gas LP Gas Propane Open Burner Main Burner Injectors Ø 2 45 mm Ø 1 50 mm Pilot Burner PF Option Only 0 30 0 20 Griddle Main Burner Ø 2 10 mm Ø 1 30 mm Pilot Burner 0 35 0 23 Main Burner Ø 2 60 mm Ø 1 60 mm Pilot Burner 0 35 0 23 Low Fire Ø 1 5 mm Ø 0 95 mm Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Operating Pressure 0 95 kPa 2 ...

Страница 26: ... with Flame Failure 227384 Knob Open Burner with Pilot Flame Failure 228167 Thermocouple 320 mm Front 228166 Thermocouple 600 mm Rear Griddle 014105 Burner 032210 Injector Nat Gas Ø 2 10mm 032130 Injector LP Gas Propane Ø 1 30mm 227403 Gas Control with Pilot Flame Failure 227384 Knob Griddle 019215K Pilot Burner Kit 026488 Pilot Injector Nat Gas 0 35 019217 Pilot Injector LP Gas Propane 0 23 01942...

Страница 27: ...LH 228106 Oven Rack RN8510G 227896 Oven Rack RN8610G RN8810G General 227015 Pot Stand Trivet 228884 Spill Tray 750mm RN8510G Series 228883 Spill Tray 450mm RN8610G Series 228882 Spill Tray 600mm RN8810G Series 229674 Rear Roller Assy 227850 Adjustable Leg 150mm Gas Conversion Kits Accessories 228566 Griddle Scraper Tool 228567 Smooth Plate Scraper Blades Pack of 5 blades 228797 750mm Plinth Kit 22...

Страница 28: ......

Отзывы: