8
Installation
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Assembly
NOTE:
All Models are delivered completely assembled. No further assembly is required. Refer to
the information below for installation instructions.
This appliance is fitted with adjustable feet to enable appliance to be positioned securely
and level. This should be carried out on completion of gas connection. Refer to ‘Gas
Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
Rear Roller Kit. For installation details, refer to instructions supplied with each kit.
Plinth Kit. For installation details, refer to instructions supplied with each kit.
1.
Check all feet are securely fitted.
2.
Adjust feet to make appliance steady and level.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1.
It is essential that gas supply is correct for appliance being installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a.
Gas Type
the appliance has been supplied for is shown on coloured stickers located above gas
connection and on rating plate. Check this is correct for gas supply appliance is being installed
for. Gas conversion procedure is detailed in this manual.
b.
Supply Pressure
required for this appliance is shown in 'Specifications' section of this manual.
Check gas supply to ensure adequate supply pressure exists.
c.
The Input Rate
of this appliance is shown on Rating Plate and in ‘Specifications’ section of this
manual. Input rate should be checked against available gas supply line capacity.
Particular
note should be taken if appliance is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on
appliance with as few tees and elbows as possible to give maximum supply volume.
2.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as shown in ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Regulator connections are
3
/
4
" BSP female.
Connection to appliance is
3
/
4
" BSP male.
(Refer to ‘Specifications’ section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
Combustible Surface
Non Combustible Surface
Left / Right Hand Side
50mm
0mm
Rear
50mm