background image

18 

 

NOTE: 

 

These  conversions  should  only  be  carried  out  by  qualified  persons.    All  connections 

must be checked for leaks before re-commissioning the appliance. 

 

Adjustment of components that have adjustments / settings sealed (e.g. paint sealed) 

can  only  be  adjusted  in  accordance  with  the  following  instructions  and  shall  be  re-

sealed before re-commissioning this appliance. 

 

For  relevant  gas  specifications  refer  to 

Gas  Specifications  Tables

’ 

at  rear  of  this  

section. 

 

1.  Remove the following:- 

 

Gas control knob. 

 

Water control knob. 

 

Control panel. 

 

2.  Connect a manometer to upper test point (Line Pressure) on gas 

control valve.  Turn On gas and ensure supply pressure is as 

shown in Gas Specifications Table at rear of this section. 

3.  Remove main burner injectors and replace with correct size 

injectors as shown in Gas Specifications Table. 

 

 

 

 

1.  Remove the following:- 

 

Gas supply tube to pilot burner. 

 

NOTE: Appliances  fitted  with  piezo  igniter  electrodes, 

remove  electrode  from  mounting  bracket  before 

unscrewing pilot supply tube. 

 

2.  Remove pilot burner injector and replace with correct size 

injector as shown in ‘Gas Specifications Table’ at rear of this 

section. 

3.  Refit the following:- 

 

Gas supply tube to pilot burner. 

 

Piezo igniter electrode. 

 

 

 

 

1.  Light main burners and check flame size on ‘Low’ position. 

 

Adjust  low  fire  adjustment  screw  on  burner  gas  control 

valve to obtain desired flame size. 

 

NOTE: 

Low  Fire  Screw

’ 

should  be  sealed  with  coloured 

paint on completion of low fire adjustment. 

 

2.  Refit the following:- 

 

Gas control knob. 

 

Water control knob. 

 

Control panel. 

Gas Control 

Valve 

Line Pressure 

Thermocouple 

Piezo 

Igniter 

Pilot Burner 

Main Burner 

Injector 

Low Fire Adjust 

Screw 

Содержание PCB8140G

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Pasta Cooker PC8140G PCL8140G PCB8140G PCLB8140G 230008 20 For use in GB IE...

Страница 2: ...0 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free...

Страница 3: ...on Requirements Unpacking Location Clearances Assembly Gas Connection Water Connection Drainage Connection Commissioning Operation Guide Description of Controls Before Use Filling the Tank Lighting Pi...

Страница 4: ...adapting appliance to conditions for use in that country GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTE...

Страница 5: ...t 1 4 165 x 165mm Basket 1 2 320 x 165mm Australia New Zealand UK Only Category II2H3P Flue Type A1 NOTE Measure burner operating pressure at upper test point Supply Pressure on gas control valve loca...

Страница 6: ...ion point is located 152mm from left hand side 36mm from rear of appliance 124mm from floor and is entered from beneath appliance An optional rear connection is available Connection is 3 4 BSP male A...

Страница 7: ...5...

Страница 8: ...manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Remove all packaging and transit protection from appliance including all prot...

Страница 9: ...following minimum installation clearances are to be adhered to This model is delivered completely assembled Ensure that the adjustable feet are securely attached NOTE This appliance is fitted with adj...

Страница 10: ...sible NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as shown in Gas Conversion Section in this manual Ensure regulator is converted to correct gas...

Страница 11: ...boiling water Drain connection is R1 BSP drain overflow The following commissioning checks must be carried out before pasta cooker is handed over for use to ensure that unit operates correctly and ope...

Страница 12: ...ning A commercial heavy duty gas fired pasta cooker using an infra red burner system Available in single model type This model is fitted with single main burner and pilot burner and is controlled by a...

Страница 13: ...of water supply nozzle that just causes water to continually flow out of overflow This method provides Maintained water level for cooking Skimming or flushing effect to prevent cooking water becoming...

Страница 14: ...gulated between High Flame and Low Flame position to regulate cooking temperature 3 It will take approximately 30 minutes to heat water in tank from 20 C to 100 C IMPORTANT THE USE OF ROCK SALT IS NOT...

Страница 15: ...appliance DO NOT use any chloric or bleaching detergents to clean appliance Ensure that any detergent or cleaning material has been completely removed after each cleaning DO NOT use saline or sulphuri...

Страница 16: ...l using a damp cloth lightly moistened with a solution of mild detergent and hot water Dry the control panel thoroughly using a dry clean cloth 5 At the end of each day or at end of each shift Clean t...

Страница 17: ...l valve spindles and can be removed when cleaning the control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleane...

Страница 18: ...ks out satis but problem still persists Gas control valve is defective and needs replacement Call service provider Pilot Burner delay in ignition of main burners Check operating pressure as shown in I...

Страница 19: ...17 PC8140G Pasta Cooker...

Страница 20: ...in burner injectors and replace with correct size injectors as shown in Gas Specifications Table 1 Remove the following Gas supply tube to pilot burner NOTE Appliances fitted with piezo igniter electr...

Страница 21: ...gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in Installation Section of this manual 3 Ensure any adjustments...

Страница 22: ...mm 1 90mm Pilot Burner Injectors 0 62 0 35 Low Fire Screw 1 55mm 1 55mm High Fire Screw Fully Out c c w Fully Out c c w Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 92 kPa 2...

Страница 23: ...odels can only be converted between Nat Gas LP Gas and Butane but not Town Gas Refer to Gas Conversion and Specifications section in this manual for further details Main Burner Injectors 3 10mm 1 80mm...

Страница 24: ...Water Valve 018095 Piezo H T Lead 227508 Piezo Ignitor 022575 Burner Kit General 238674 Pasta Basket LH 1 6 165 x 125mm 238819 Pasta Basket RH 1 6 165 x 125mm 229707 Pasta Cooker Basket Drain Tray 22...

Страница 25: ......

Отзывы: