4
Specifications
Model Numbers Covered in this Specification
FN[1]8120GE
‘FAST FRI’ GAS FRYER
(Single Tank - 20Ltr).
FN[1]8226GE
‘FAST FRI’ GAS FRYER
(Twin Tank - 26Ltr per Tank).
FN[1]8130GE
‘FAST FRI’ GAS FRYER
(Single Tank - 31Ltr).
NOTE:
[1]: - Model Options;
- -
Standard.
L
- Low Back.
B
- Bold Front.
LB
- Low Back and Bold Front.
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
NOTE:
(
*
) M
easure burner operating pressure at Lower Test Point (Out) on the gas control valve, with
both burners operating at 'High Flame' setting. Refer to ‘Gas Conversion and Specification’
Section for further details.
Natural Gas (G20)
Propane (G31)
Heat Input (nett)
22.5 kW
22.5 kW
Gas Rate
2.26 m
3
/hr 1.75
kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
9.8 mbar
25 mbar
Gas Connection
3
/
4
” BSP Male
Natural Gas
LP Gas (Propane)
Input Rating (N.H.G.C.)
90 MJ/hr
90 MJ/hr
Supply Pressure
1.13 - 2.00 kPa
2.75 - 3.00 kPa
Burner Operating Pressure (*)
0.98 kPa
2.50 kPa
Gas Connection
¾” BSP Male
Natural Gas
LP Gas
Input Rating (N.H.G.C.)
90 MJ/hr
90 MJ/hr
Supply Pressure
1.13 - 2.00 kPa
2.75 - 3.00 kPa
Burner Operating Pressure (*)
0.98 kPa
2.50 kPa
Gas Connection
¾” BSP Male