11
Installation
2.
A suitable joining compound which resists the breakdown action of LPG must be used on every gas
line connection, unless compression fittings are used.
Connection to appliance is
3
/
4
” BSP male.
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
3.
Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
unit is level and at correct height.
4.
Connect gas supply to appliance.
5.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
6.
Check gas supply pressure is as shown in Specifications section, Gas Supply Requirements
table.
NOTE: Measure gas supply pressure at Upper Test Point (Supply Pressure) on the gas control
valve.
7.
Light Pilot Burners. Refer to Operation section, Lighting Pilot Burners.
8.
Check pilot flame size. Re-adjust if required, using pilot adjusting screw (See Fig 3 below), and as
shown in Gas Conversion and Specifications section, Pilot Burner Flame Adjustment.
9.
Light the Main Burners. Refer to Operation section, Lighting Main Burners.
10. Verify Supply Pressure is still correct.
11. Check Main Burner operating pressure (Adjust, using
Operating Pressure Adjusting Screw on Gas Control
Valve, see Fig 3), and as shown in Gas Conversion
and Specifications section, Main Burner Operating
Pressure Adjustment.
NOTE: Insufficient gas supply line capacity, indicated by
operating pressure drop during maximum gas
supply demand, is NOT ACCEPTABLE and may
invalidate the manufacturers warranty for this
appliance.
Ensure the tank(s) is / are filled with either water or oil prior to starting Main
Burners otherwise the fryer tank(s) may be damaged.
Caution
IMPORTANT:
Control Panel ‘ON / OFF’ Key provides ‘ON / OFF’ control of Controller and Main Burner
heating cycles ONLY.
Gas Valve Control Knob is used to turn the Gas System ‘ON / OFF’ as well as providing Pilot
Ignition and Pilot Standby functions.
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning
Supply Pressure
Test Point
Operating Pressure
Test Point
Pilot Adjusting
Screw
Operating Pressure
Adjusting Screw
Fig 3