3
Specifications
Model Numbers Covered in this Specification
FN
[1]
8130GHPO 'FAST FRI' GAS FRYER (Single Tank - 31 ltr).
NOTE:
[1] - Back Options;
-
- Standard Models.
L
- Low Back Models.
General
A commercial heavy duty, gas fired fryer having a high power infra red burner system which an
intense even heat through the tank.
This model is fitted with dual main burners with twin gas controllers which work independently for
each burner and are ignited with a fully electronic ignition system.
This fryer features an Over Temperature Safety Cut Out system with Full Flame Failure Safety
Controls and lock out alarm indicators on the front control panel.
State of the art gas controls with electronic thermostat sensitive to changes in oil temperature which
improves both recovery and output.
An open tank design to make cleaning a simple and easy task.
Optional Accessories
This appliance can be fitted with the following optional accessories, (refer to the 'Replacement Parts
List' for details).
•
Rear Roller Kit.
•
Plinth Kit.
Gas Supply Requirements
NOTE:
(*)
The burner operating pressure is to be measured at the lower test point (Out) on
the gas control valve located behind the access door and through the access hole
in the control panel, this is to be carried out with both burners operating at the
'High Flame' setting. Refer to the 'Gas Conversion and Specification' Section for
further details.
Natural Gas
LP Gas (Propane)
Input Rating
140 MJ/hr
140 MJ/hr
(N.H.G.C.)
(133,000 Btu/hr)
(133,000 Btu/hr)
Operating Pressure
1.13 - 3.40 kPa
2.75 - 3.40 kPa
(4.5” - 13.5” w.c.)
(11” - 13.5” w.c.)
0.95 kPa (*)
2.6 kPa (*)
(3.6” w.c.)
(10.5” w.c.)
Gas Connection
¾” BSP Male
Burner Pressure