Installation

 

Installation Requirements 

NOTE: 



It is most important that this Fryer is installed correctly and that the operation is 
correct before use.  Installation shall comply with local electrical, gas and health and 
safety requirements. 



This appliance shall be installed with sufficient ventilation to prevent occurrence of 
unacceptable concentrations of health harmful substances in the room, appliance is 

installed in. 

 

Waldorf ‘FAST FRI’ gas fryers are designed to provide years of satisfactory service, and correct installation 

is essential to achieve the best performance, efficiency and trouble-free operation. 
This appliance must be installed in accordance with National installation codes and in addition, in 
accordance with relevant National / Local codes covering gas and fire safety. 

Australia / New Zealand

 

AS 5601.1 

- Gas Installations. 

Australia / New Zealand:

 

AS / NZS 3000  - Wiring Rules. 

United Kingdom:

 

Gas Safety (Installation and Use) Regulations 1998. 

United Kingdom:

 

BS 7671 

- Requirements for Electrical Installations. 

Ireland:

 

IS 820 

- Non Domestic Gas Installations. 

 

Installations must be carried out by qualified service persons only.  Failure to install 

equipment to the relevant codes and manufacturer’s specifications shown in this section will 
void the warranty. 
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be 
adjusted by an authorised service agent.  They are not to be adjusted by the installation 

person. 

 

Unpacking 



Remove all packaging and transit protection from appliance including all protective plastic coating 
from door outer panel and exterior stainless steel panels. 



Check equipment and parts for damage.  Report any damage immediately to carrier and distributor. 



Report any deficiencies to distributor who supplied appliance. 



Check available gas supply is correct to as shown on rating plate located on inside of door. 



Check the following parts have been supplied with the appliance:- 

 

 FN8120GE 

FN8226GE 

FN8130GE 

Baskets 2 

Basket Grids 

Lid 1 

Adjustable Legs 

Drain Stick 

Rear Rollers 

2  (NZ only, Rollers fitted). 

 

Location 

1. 

This appliance must be installed in a suitably ventilated room to prevent dangerous build up of 

combustion products. 

2. 

Installation must allow for a sufficient flow of fresh air for combustion air supply.  Combustion air 

requirements: 

 

Combustion Air Requirements 
All Gas Types 

24 m³/hr minimum. 

 

3. 

Position the appliance in its approximate working position. 

4. 

All air for burner combustion is supplied from beneath appliance.  Legs must always be fitted and no 

obstructions placed beneath or around base of appliance, as obstructions will cause incorrect 
operation and / or failure of appliance. 

 

NOTE: Do not obstruct or block appliance flue.  Never directly connect a ventilation system to 

appliance flue outlet. 

Содержание FN8120GE

Страница 1: ...O p e r a t i o n M a n u a l FN8120GE FN8226GE FN8130GE Fast Fri Gas Fryer E l e c t ro n i c a l l y C o n t ro l l e d Date Purchased Serial Number Dealer Service Provider 228638 16 For use in GB I...

Страница 2: ...es tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455...

Страница 3: ...itting Rear Rollers Electrical Connection Gas Connection Commissioning Operation 12 Operation Guide Description of Controls Filling the Tank s Controller Basic Programming Mode Entering the Controller...

Страница 4: ...27 Timing Mode Temperature Offset Temperature Display Mode Programming the Melt Cycle Setting the Temperature Units System Programmable Default Settings Gas Conversion and Specifications 30 Conversion...

Страница 5: ...ppliance must NOT be left on unattended It is recommended that a regular inspection is made by a competent service person to ensure correct and safe operation of your appliance is maintained DO NOT st...

Страница 6: ...ac 1P N E 50Hz 0 5A Electrical Connection The power cord comes fitted with Australia NZ models 10A 3 pin plug United Kingdom models 13A 3 pin fused plug Natural Gas LP Gas Propane Input Rating 90MJ hr...

Страница 7: ...5 Dimensions FN L 8130GE 3 3 2 1 2 1 3 2 1 FN L 8226GE 3 2 1 3 3 2 1 2 1 FN L 8120GE 3 2 1 3 3 2 1 2 1 1 Primary Gas Entry Point 2 Optional Gas Entry Point 3 Electrical Entry Point...

Страница 8: ...ected e g paint sealed by manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protecti...

Страница 9: ...y attached NOTE This appliance is fitted with adjustable feet to enable it to be positioned securely and level on uneven floors This should be carried out on completion of gas connection Refer to Gas...

Страница 10: ...rear leg housings 3 Fit rear roller to rear leg housing and align screw hole in side of rear leg housing with threaded hole in rear roller 4 Secure the rear roller to the leg support with bolt suppli...

Страница 11: ...meets the following requirements NOTE ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON 1 It is essential that the gas supply is correct for the appliance being installed and tha...

Страница 12: ...and Specifications section Pilot Burner Flame Adjustment 9 Light the Main Burners Refer to Operation section Lighting Main Burners 10 Verify Supply Pressure is still correct 11 Check Main Burner oper...

Страница 13: ...the calibration of the thermostat If a discrepancy is found thermostat calibration should be referred to the supplier d Ensure each operator has been instructed in areas of correct lighting operation...

Страница 14: ...r should not be adjusted by the user operator Caution O Fig 4 Piezo Igniter Gas Control Valve OFF Position PILOT Burner HIGH Flame Flame Failure Button Single Tank Models Only NOTE Only one temperatur...

Страница 15: ...to access the parameter setting required a If LoC is displayed control panel is locked which will prevent any accidental change to the operating mode b To access parameters whilst LoC is displayed on...

Страница 16: ...ol panel display Refer to Controller Advanced Programming Mode section to change Heating will automatically cycle at a lower temperature to gently melt the shortening THE OPERATOR MUST TAKE GREAT CARE...

Страница 17: ...Items 1 to 4 above FN8226GE Fryer Twin Tank 1 Rotate gas control knob to Pilot position and hold knob depressed 2 Press the piezo igniter until pilot ignites 3 Hold gas control knob depressed for app...

Страница 18: ...ntroller Refer to Controller Advanced Programming Mode section for controller advanced programming If Melt Cycle is turned ON If Melt Cycle is turned OFF If t 0 selected in Advanced Program Settings d...

Страница 19: ...ess and rotate gas control valve fully clockwise to the Off position b The Pilot burners will extinguish IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner con...

Страница 20: ...ining and Daily Cleaning 1 At end of each day or at end of each shift if frying schedule is heavy frying medium should be drained and filtered into a receptacle 2 Always filter fryer when cool zone un...

Страница 21: ...k has been drained use a ladle or small pan with a handle and dip into hot frying medium from container and pour around sides and bottom of tank to wash out crumbs and particles adhering to tank 9 Con...

Страница 22: ...yer and rinse thoroughly with water Use a 1 part vinegar to 15 parts water solution to rinse tank and neutralise any cleaner residue If this proves unsuitable for cleaner being used use a weaker solut...

Страница 23: ...fried Continued overheating of oil Check thermostat setting Turn down heat to around 140 C Standby when use is quiet Overloading Maintain 1 8 ratio of food to frying medium Gumming Heating frying medi...

Страница 24: ...ficient turnover of oil Maintain a minimum quantity of oil in fryer for more rapid turnover or increase quantity of food fried in fryer Replace with fresh oil every 3 to 5 days Continual frying with e...

Страница 25: ...ure Call for service Faulty thermocouple Call for service Faulty overtemp Call for service Faulty gas control valve Call for service Pilot Burner goes Out during operation Low fluctuating gas pressure...

Страница 26: ...NL8120GE Fryer Schematic T C FLAME FAILURE VALVE SIT M1 A MAIN GAS CONTROL SIT NOVA 820mV 24V 50Hz THERMOSTAT OVER TEMP IGNITION L H PILOT T C R H PILOT CROSS LIGHTING TRANSFORMER 24v P N FUSE 2 0 Amp...

Страница 27: ...er Schematic TH MAIN GAS CONTROL SIT NOVA 820mV 24v 50Hz MAIN GAS CONTROL SIT NOVA 820mV 24v 50Hz PILOT PILOT T C TC IGNITION OVER TEMPS THERMOSTAT IGNITION FAST DIGITAL CONTROLLER FAST DIGITAL CONTRO...

Страница 28: ...E FNL8130GE Fryer Schematic T C FLAME FAILURE VALVE SIT M1 A MAIN GAS CONTROL SIT NOVA 820mV 24V 50Hz THERMOSTAT OVER TEMP IGNITION L H PILOT T C R H PILOT TRANSFORMER 24v P N FUSE 2 0 Amp FAST DIGITA...

Страница 29: ...cked Unlock the control panel refer to Controller Basic Programming Mode Entering the Controller Basic Settings and repeat from Item 2 above Timing Mode 1 One of the following options will display Str...

Страница 30: ...perature offset option press either Timer 1 or Timer 3 key to change selection 3 Press Program Key P to confirm the change and the display will step on to Temperature Display parameter Temperature Dis...

Страница 31: ...oximately 3 seconds Or not pressing any keys for 2 minutes during Advanced Programming Mode the appliance will exit Advanced Programming Mode and return to Idle Mode System Programmable Default Settin...

Страница 32: ...his section Main Burners 1 Remove main burner injectors and replace with correct size injectors as shown in Gas Specifications table Pilot Burners 1 Remove the following Gas supply tube to the pilot b...

Страница 33: ...ermocouple and thermopile is correct and main burner pilot flame ignites main burners satisfactorily b Adjust pilot flame size by adjusting Pilot Burner Adjusting Screw Pilot burner flame should be ap...

Страница 34: ...h Flame setting Refer to Gas Conversion and Specification Section for further details Natural Gas G20 LP Gas Propane G31 Main Burner Injectors 3 10mm 1 90mm Pilot Burner Injectors Non CE 0 62 0 35 CE...

Страница 35: ...17 Gas Control 24V 229158 Gas Valve Cable Plug 24V FN8120GE FN8226GE Only 229159 Gas Valve Cable Plug 24V FN8130GE Only 019237 Flame Failure Valve FN8120GE FN8130GE Only 018095 Piezo H T Lead 020119 P...

Страница 36: ...228577 Basket Tray FN8226GE 228578 Basket Tray FN8130GE 228419 Lid FN8120GE FN8226GE 228575 Lid FN8130GE 229674 Rear Roller Assy 227850 Leg Adjustable 150mm Flush Stud Gas Conversion Kits Accessories...

Страница 37: ......

Отзывы: