background image

Installation 

Installation Requirements 

NOTE: 



It is most important that this appliance is installed correctly and that operation is 
correct before use.  Installation shall comply with local, gas, health and safety 
requirements. 



This appliance shall be installed with sufficient ventilation to prevent occurrence of 
unacceptable concentrations of health harmful substances in room, the appliance is 

installed in. 

 

Waldorf ‘FAST FRI’ Gas Fryers are designed to provide years of satisfactory service and correct installation 

is essential to achieve the best performance, efficiency and trouble-free operation. 
This appliance must be installed in accordance with National installation codes and in addition, in 

accordance with relevant National / Local codes covering gas and fire safety. 

 

Australia / New Zealand:

 

AS 5601.1 

- Gas Installations. 

United Kingdom:

 

Gas Safety (Installation and Use) Regulations 1998. 

Ireland:

 

IS 820 

 - Non Domestic Gas Installations. 

 

Installations must be carried out by qualified service persons only.  Failure to install 
equipment to relevant codes and manufacturer’s specifications shown in this section will void 

the warranty. 
Components having adjustments protected (e.g. paint sealed) by manufacturer, are only to be 
adjusted by an authorised service agent. They are not to be adjusted by the installation 

person. 

 

Unpacking 



Remove all packaging and transit protection from appliance including all protective plastic coating 
from door outer panel and exterior stainless steel panels. 



Check equipment and parts for damage.  Report any damage immediately to carrier and distributor. 



Report any deficiencies to distributor who supplied appliance. 



Check available gas supply is correct to that shown on rating plate located on inside of access door. 



Check the following parts have been supplied with appliance: 

 

 FN8120G 

FN8226G 

FN8130G 

Baskets 2 

Basket Trays 

Lid 1 

Drain Stick 

Location 

1. 

This appliance must be installed in a suitably ventilated room to prevent dangerous build up of 

combustion products. 

2. 

Installation must allow for a sufficient flow of fresh air for combustion air supply.  Combustion air 

requirements:- 

 

Combustion Air Requirements 
All Gas Types 

24 m³/hr minimum. 

 

3. 

Position appliance in its approximate working position. 

4. 

All air for burner combustion is supplied from beneath the appliance.  Legs must always be fitted 

and no obstructions placed beneath or around the base of the appliance, as obstructions will cause 
incorrect operation and / or failure of appliance. 

 

NOTE:  Do not obstruct or block the appliances flue.  Never directly connect a ventilation system to 

the appliance flue outlet. 

Содержание Fast-Fri FN8120G

Страница 1: ...s t a l l a t i o n a n d O p e r a t i o n M a n u a l Fast Fri Gas Fryer FN8120G FN8226G FN8130G Date Purchased Serial Number Dealer Service Provider 228573 20 For use in GB FNL8120G FNL8226G FNL81...

Страница 2: ...es tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455...

Страница 3: ...embly Fitting Rear Rollers Gas Connection Commissioning Operation 10 Operation Guide Description of Controls Filling the Tank s Lighting Pilot Burners Lighting Main Burners Setting the Operating Tempe...

Страница 4: ...UST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE...

Страница 5: ...t Out on gas control valve with both burners operating at the High Flame setting Refer to Gas Conversion and Specification Section for further details Natural Gas LP Gas Propane Input Rating 90MJ hr 9...

Страница 6: ...GAS FRYERS FN L 8120G Single Tank FN L 8226G Twin Tank FN L 8130G Single Tank FN L 8130G GAS FRYER 1 Primary Gas Entry Point 2 Optional Gas Entry Point 1 Primary Gas Entry Point 2 Optional Gas Entry...

Страница 7: ...only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective...

Страница 8: ...curely attached NOTE This appliance is fitted with adjustable feet to enable it to be positioned securely and level on uneven floors This should be carried out on completion of gas connection Refer to...

Страница 9: ...t from rear leg housings 3 Fit rear roller to rear leg housing and align screw hole in side of rear leg housing with threaded hole in rear roller 4 Secure rear roller to leg support with bolt supplied...

Страница 10: ...alled for Gas conversion procedure is shown in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check gas supply to ensure that adequate supp...

Страница 11: ...f this manual b Thermostat operation check should be carried out by filling fryer with oil shortening to oil FILL LEVEL mark at rear of tank refer to Filling the Tank in Operation Section of Manual an...

Страница 12: ...er Fig 4 Gas Control Valve OFF Position PILOT Burner HIGH Flame GREAT CARE MUST BE TAKEN BY OPERATOR TO USE THE FRYER SAFELY TO GUARD AGAINST RISK OF INJURY AND FIRE DO NOT LEAVE FRYER UN ATTENDED DUR...

Страница 13: ...he shortening until it is just liquefied Do not bring the shortening up to high temperature as handling of hot shortening is dangerous If pre melting of shortening is not possible carefully cut the sh...

Страница 14: ...T and hold depressed 2 Depress the piezo igniter until pilot ignites 3 Continue holding the gas control knob depressed for approx 10 to 15 seconds after igniting pilot burner pilot burner should remai...

Страница 15: ...0 C Turning OFF the Fryer To the Pilot Position a Depress and rotate the gas control valve clockwise to the Pilot position b The main burners will extinguish and the Pilot will remain alight To the Of...

Страница 16: ...rying schedule is heavy frying medium should be drained and filtered into a receptacle 2 Always filter fryer when cool zone under burners is hot and liquid A cold fryer heated up won t drain because f...

Страница 17: ...s been drained use a ladle or small pan with a handle and dip into hot frying medium from container and pour around sides and bottom of tank to wash out crumbs and particles adhering to tank 9 Continu...

Страница 18: ...yer and rinse thoroughly with water Use a 1 part vinegar to 15 parts water solution to rinse tank and neutralise any cleaner residue If this proves unsuitable for cleaner being used use a weaker solut...

Страница 19: ...oes are cured correctly Excessive quantities of breading or batter Remove surplus breading or batter Placing food in frying medium direct from freezer Allow frozen foods to thaw before frying Surplus...

Страница 20: ...ts Oil overheating Check oil temperature by using a thermometer or thermocouple Rapid breakdown of oil Use a stable frying oil Use of unrefined oils Dripping smokes at lower temperature than refined a...

Страница 21: ...ice Faulty thermocouple Call for service Faulty overtemp Call for service Faulty gas control valve Call for service Pilot Burner goes Out during operation Low fluctuating gas pressure Call for service...

Страница 22: ...HERMOPILE L H PILOT T C R H PILOT CROSS LIGHTING T C FLAME FAILURE VALVE SIT M1 A MAIN GAS CONTROL SIT NOVA 820mV FN8130G FNL8130G Fryer Single Tank THERMOPILE IGNITION TP TH OVER TEMP THERMOSTAT TH T...

Страница 23: ...ematics FN8226G FNL8226G Fryer Double Tank TH TP TH TP MAIN GAS CONTROL SIT NOVA 820mV MAIN GAS CONTROL SIT NOVA 820mV PILOT PILOT T C THERMOPILE TC THERMOPILE IGNITION IGNITION TP TH TH TP OVER TEMPS...

Страница 24: ...urners 1 Remove main burner injectors and replace with the correct size injectors as shown in Gas Specifications table Pilot Burners 1 Remove the following Gas supply tube to pilot burner NOTE Applian...

Страница 25: ...and thermopile is correct and main burner pilot flame ignites main burners satisfactorily b Adjust pilot flame size by adjusting Pilot Burner Adjusting Screw Pilot burner flame should be approximately...

Страница 26: ...at the High Flame setting Refer to Gas Conversion and Specification Section for further details Natural Gas G20 LP Gas Propane G31 Main Burner Injectors 3 10mm 1 90mm Pilot Burner Injectors Non CE 0...

Страница 27: ...lot Injector Natural Gas G20 0 45 UK Only 018089K Gas Control Kit 018095 Piezo H T Lead 227508 Piezo Ignitor 022575 Main Burner Kit 018145 Thermostat Knob 018021K Thermostat 018022K Overtemperature Th...

Страница 28: ...version Kits Accessories Optional 228793 450mm Fryer Plinth Kit 228794 600mm Fryer Plinth Kit Model Gas Type to Convert to Australia New Zealand Only UK Only Nat Gas LPG Nat Gas LPG FN8120G FN8226G FN...

Страница 29: ......

Отзывы: