Sound Parameter
Blofeld User´s Manual
76
play only one single note on a 16 beat rhythm with
lengths set to 1/8.
Note that this parameter only affects notes of the same
pitches. If you want to control the lengths of notes of
different pitches, use the
Length
or
Arrpegiator Length
parameters.
•
If
on
is selected, the Note Off message of the
previous note is allowed to be sent after a Note On
message of the next note with the same pitch. This
setting can be nice with arpeggios triggering
sounds with slow attack.
•
If
off
is selected, the Note Off message of the
previous note is sent right before the next note
with the same pitch is started.
Timing Factor
0...127
Determines how much the
Arp Timing
parameter affects
an arpeggio step. If
Timing Factor
is set to
0
, the settings
in
Arp Timing
are completely ignored and the arpeggio is
played back without any shuffled timing. Settings from
1
to
127
increase the shuffling of the notes depending on
the setting in the
Arp Timing
parameter.
Timing Factor
also works on ROM patterns; these are set up with
standard swing rhythm.
Velocity
Each Note / First Note / Last Note
/ fix 32 / fix 64 / fix 100 / fix 127
Determines how velocity is interpreted in the arpeggio.
Note that each arpeggio step might have an additional
positive or negative offset set by the
Arp Accent
parameter.
•
If
Each Note
is selected, each note of the arpeggio
is played back with the velocity that you originally
played.
•
If
First Note
is selected, the first note you played
sets the velocity for all arpeggio steps.
•
If
Last Note
is selected, the last note you played
sets the velocity for all arpeggio steps.
•
If one of the fix values is selected, all notes will be
played with the selected velocity.
Pat. Length
1...16
Sets the length of the rhythm pattern. This parameter is
also valid when
Pattern
is set to
Off
or if one of the ROM
patterns is selected. Note that you can only edit a
particular step in the
Step Data
pages when its position is
within the range of the
Pattern Length
parameter.