31
Connection
ENG
4.3 Through-wiring
Luminaires with through-wiring can be
linkedtooneanotherviathepre-mounted
plug-inconnection“GST18i3S”.Theselumi-
nairesareidentifiedbytheletter
D
inthe
modelnumber,forexampleSAHQ88D.
Toconnectthefirstluminaire,aconnecting
cableisrecommended,whichcanbefound
intheWaldmannrangeofaccessories.
Formoreinformationontheaccessoriesof
thisluminaire,pleasevisittheWaldmann
homepageat:www.waldmann.com
WARNING
Danger of death due to electric shock.
X
Beforeestablishingordisconnect-
ingtheplug-inconnection,discon-
necttheluminairefromthepower
supply.
NOTE:
In luminaires with through-wiring
connectedinseries,thetotalcurrentcon-
sumption must not exceed
2 A
.The cur-
rentconsumptionofthedifferentluminaire
modelscanbefoundinthefollowingtable:
Luminaire model
Current con-
sumption
SAHQ44xD
SAHQ66xD
SAHQ88xD
SAH124xD
SAH139xD
SAH154xD
0.10A
0.15A
0.20A
0.13A
0.21A
0.28A
Tab.3:Currentconsumptionperluminaire.
X
Connecttheluminairestooneanother
using the device plug-in connection
“GST18i3S”.