44
Dismounting
ENG
13. Dismounting
WARNING
Danger of death due to electric shock.
X
Disconnect the luminaire from the
power supply.
X
Have it performed by a skilled elec-
trician only.
CAUTION
Risk of injury caused by falling light
head.
Personal injury and material damage.
X
Hold light head.
X
Dismount the luminaire in reverse order
to mounting, Kapitel 3 „Mounting“ auf
14. Disposal
The luminaire is subject to the European
WEEE Directive.
X
Dispose of the luminaire separately
from domestic waste using the agen-
cies responsible for disposal and desig-
nated by the authorities. Proper disposal
avoids adverse effects on man and the
environment.
15. Technical Data
NOTE:
The data given on the rating plate of
the luminaire apply. The rating plate can be
found on the cover at the light head.
15.1 Dimensions
Designation
Value
TWIN-U
(U form)
Light heads
760 x 1120 x 35.5 mm
Base of the light:
500 x 470 x 10 mm
TWIN-T
(T form)
Light heads
320 x 1875 x 35.5 mm
Base of the light:
350 x 450 x 10 mm
Total height
2035 mm
Tab. 6: Dimensions.
15.2 Electrical values
Designation
Value
Voltage range
220-240 V
Frequency
range
50/60 Hz
Power con-
sumption
The power consump-
tion is specified on
the rating plate of the
luminaire.
Starting current 12 A
t = 1.83 ms
Zero crossing
solid state relay
Operating unit
Integrated into
the light head
Tab. 7: Electrical values.