21
Connection
ENG
4. Connection
4.1 Connecting the luminaire to the
supply voltage (SELV version)
To connect the luminaires, connecting
cables are recommended, which can be
found in the Waldmann range of acces-
sories.
NOTICE
Material damage caused by wrong
mains voltage.
Damage or destruction of the luminaire.
X
The connection must be conducted
by a trained electrician only.
X
Operate the luminaire at safety
extra low voltage (SELV) only.
X
Observe the pin assignment and
the socket assignment.
X
Use connecting cable with strands
which have a conductor cross-sec-
tion of at least 0.34 mm². For
through-wiring minimum 1.5 mm².
X
USA and Canada:
This device
must be connected to a power
supply unit of class 2.
There are different pin assignments availa-
ble for the luminaire:
Type A
Type B
To be able to connect the luminaire, you
must know the pin assignment of the
luminaire.
NOTE:
The pin assignment designation
can be found on the rating plate of the
luminaire.
X
Check which designation is on the rat-
ing plate.
X
Determine the pin assignment accord-
ing to the tables.
3
1
4
2
No. Designation
1
DC +
2
Not used
3
DC -
4
Not used
Tab. 3: Plug M12-A-4, pin assignment Type A.
3
1
4
2
5
No. Designation
1
Not used
2
Not used
3
DC -
4
DC +
5
Not used
Tab. 4: Plug M12-A-5, pin assignment Type B.
X
Connect a suitable socket with the
A-coded plug.