500.0024-A
8
Subject to technical changes
7.
Then enter the new code (8 digits) and confirm again with the ENTER key.
8.
Enter the new code again to confirm it, and press the ENTER key to complete the
confirmation. The display shows: "Code saved".
9.
With the door open, move the rotary opening handle counterclockwise into the
"closed" position (lock closes automatically).
10.
Enter the newly programmed code and open the lock again by moving the rotary
opening handle clockwise.
11.
If the test opening works, this guarantees that the new code has been saved and the
door can be closed.
NOTE:
If errors occur while making the change, the old code remains valid. You must start
the programming procedure from the beginning again.
3.4.2.
User code 01 (OCa2) and user code 02 (OCb2) for lock 2
Procedure:
1.
Open the door with the current codes.
2.
Leave the rotary opening handle in the "open" position.
3.
On the input unit, press the ENTER key; confirm the "Code functions" menu that is
shown on the display by pressing the ENTER key again.
4.
On the display, use the arrow key to select "Lock 2" and also confirm this with the
ENTER key.
5.
Use any arrow key to select "01 OCa2" / "02 OCb2" and confirm with the ENTER key;
the display shows "Change".
6.
Confirm this with the ENTER key and enter the existing code 1 (OCa2/ OCb2) (when
you reprogramme for the first time, this is 12223310 for code 1 and 12223320 for
code 2), and confirm with the ENTER key.
7.
Then enter the new code (8 digits) and confirm again with the ENTER key.
8.
Enter the new code again to confirm it, and press the ENTER key to complete the
confirmation. The display shows: "Code saved".
9.
With the door open, move the rotary opening handle counterclockwise into the
"closed" position (lock closes automatically).
10.
Enter the newly programmed code and open the lock again by moving the rotary
opening handle clockwise.
11.
If the test opening works, this guarantees that the new code has been saved and the
door can be closed.
3.4.3.
Master code 00 (MA1)
RECOMMENDATION:
Use the same code for the master code and user code 01 (OCa1),
or leave the master code on the factory setting (11998877). The safe cannot be opened
with the master code on its own!
Procedure: