background image

 

500.0037-A

 

Technical alterations reserved

 

 

General information

 

Every WALDIS Basic 480 safe is equipped with an electronic security lock. To operate the 
lock, please use the 500.0021 instruction manuals enclosed. You can find the 
comprehensive instruction manual, produced by the manufacturer, at: www.carl-
wittkopp.com 
(Primor 1000/3000). 
 

1.1.

 

Safety instructions 

  

 

 

 

PLEASE NOTE:

 Please make sure that no body parts get trapped between the doors and 

the case when opening and closing the doors! 
 
 
 
 
 
 
 

  

 

 

 

PLEASE NOTE:

 Before closing the doors, make sure that the handle is in the open 

position and the bolt is retracted! 
 

1.2.

 

Weight 

 
 
 

1.3.

 

Regulations and insurance 

For all safes with a net weight of less than 1000 kg, professional anchoring either during 
construction or by the client is a minimum requirement of the EN1143-1 standard. For this 
reason, all safes are equipped with 3 bore holes (2 on the back wall and 1 on the base) 
with a diameter of 16.5 mm. If it is not possible to anchor the safe in accordance with 
current regulations, the property insurance company must be informed and an alternative 
solution must be found. 
 

  

 

 

 

PLEASE NOTE: 

The safe’s warranty and certification 

terminate after attempted break-ins, 

fires and unauthorised interference with the structure! 

 

 

 

Model

 

Weight (kg)

 

Basic 480 

ca. 125 

Содержание BASIC 480

Страница 1: ...www tresore ch INSTALLATION AND MAINTENANCE INSTRUCTIONS WALDIS BASIC 480 RESISTANCE LEVEL II AS PER EN1143 1...

Страница 2: ...an EN1143 1 certified safe A high quality Swiss product checked and approved by the VdS Please read these instructions carefully before setting up your safe For any questions please contact WALDIS Tr...

Страница 3: ...1 4 Operation elemnts 2 1 5 Set up 2 Installation 2 2 1 Positioning against the building wall 2 2 2 Anchoring the safe 3 2 2 1 Important prior clarification 3 2 2 2 Preparing the safe 3 2 2 3 Anchori...

Страница 4: ...e handle is in the open position and the bolt is retracted 1 2 Weight 1 3 Regulations and insurance For all safes with a net weight of less than 1000 kg professional anchoring either during constructi...

Страница 5: ...it must be noted that a minimum distance of 440 mm to the wall must be maintained at the front in order to be able to open the door more than 90 If you also want to be able to use the full light widt...

Страница 6: ...le for installing the safe and that there are no wires pipes or similar in the area to be drilled In case of doubt an expert report should be issued to guarantee that the intended assembly location in...

Страница 7: ...pattern on the desired position and then drill the anchoring holes with 15 concrete drill and an impact drill The 15 drill hole must be at least 54 mm from the wall floor or at least 84 mm from the s...

Страница 8: ...rer s instructions Maintenance and care instructions Your safe is essentially maintenance free However we still recommend carrying out a lubricating and servicing interval as follows depending on freq...

Страница 9: ...an alarm system In these cases the alarm system has to have been functional and activated at the time the theft took place and the alarm has to have been triggered and relayed Otherwise the theft gua...

Отзывы: