At the completion of washing 
 
1. 

Open

 the milk line valve/s. 

 
2. 

Close

 the valve at the wash tub. 

 
3. Turn 

off

 the air injector/s. 

 
4. 

Close

 the air injector valve/s. 

 
5. 

Close

 the snap clamp on the rubber tube connecting the sanitary trap to the 

receiver suction line. 

 
6. 

Slowly pull the plug out of the interceptor to lower the vacuum. 

 
7. Turn 

off

 the vacuum pump/s. 

 
8. 

Remove the clusters from the cluster washers. 

 
The minimum wash water requirements for your 

Waikato

 Rotary Loopline

 are: 

 
 

Hot Water:   

10 litres per cluster 

 

Cold Water:   

15 litres per cluster 

 
Waikato Milking Systems recommend that you wash your 

Waikato

 Rotary Loopline

 

with hot water after each milking.  You should use only approved detergents and follow 
the detergent manufacturers’ instructions. 
 
Your Waikato Milking Systems dealer will set up your washing system and run through it 
with you so that you fully understand its operation. 

 

 

4

Содержание Rotary Loopline

Страница 1: ...9860110 2002 WAIKATO MILKING SYSTEMS NZ LIMITED 558 Te Rapa Rd P O Box 20055 Hamilton New Zealand Telephone 07 849 8755 International 64 7 849 8755 Facsimile 07 849 0164 International 64 7 849 0164 ww...

Страница 2: ...g Systems proprietary components on your milking machine are covered by a 12 month warranty or you may have accepted an extended warranty program which looks after your Waikato Milking System for two...

Страница 3: ...the controller to AUTOMILK will also open the milk line valve The plant vacuum will rise and milking can begin WASHING With the machine at full vacuum 1 Place all clusters into the cluster washers 2...

Страница 4: ...uum pump s 8 Remove the clusters from the cluster washers The minimum wash water requirements for your Waikato Rotary Loopline are Hot Water 10 litres per cluster Cold Water 15 litres per cluster Waik...

Страница 5: ...give consistent performance over a wide range of vacuum levels Like all vacuum regulators it can be affected by dust and dirt and its filter should be cleaned at least once a week by removing it and w...

Страница 6: ...and when they wear out Air leaking past the rubber cups will adversely affect the wash cycle VALVE SEALS Your Waikato Rotary Loopline has one main milk line valve and one jetter suction valve which c...

Страница 7: ...ason long milk tubes including the bend at the milk line end of the stainless steel tube and long pulse tubes once a season and short pulse tubes as required AUTOMATIC CLUSTER REMOVERS Consult your Wa...

Страница 8: ...short and long pulse and milk tubes and liners Replace any items which have been holed or split Sanitary trap Check for milk residues Clean both the sanitary trap and the receiver air line if residue...

Страница 9: ...unions and tighten if necessary Check claw seals shut off valves and buttons and bowls Replace if necessary Open the cooler inspect each plate and clean if necessary TWICE A SEASON Change liners milk...

Отзывы: