WAGO-SPEEDWAY 767
Connecting Data and Supply Cables
47
767-5803/000-800 8DIO 24V DC 0.5A IF (8xM12)
Manual
Version 1.1.0
To connect the S-BUS cables to fieldbus coupler and I/O modules, proceed as
follows:
1.
Disconnect the power supply from those devices on which you have
mounted the module.
2.
Connect the S-BUS cable (S1) with the OUT connection (3) of the
fieldbus coupler and the IN connection (1) of the module.
For example, if two I/O modules have been connected to the fieldbus
coupler, connect the S-BUS cables (S1, S2) to the associated IN and OUT
connections, as shown in the following figure.
3. Tighten the plugs and sockets using the knurled-head screws.
4.
Attach the S-BUS terminator (T) to the last I/O module as shown in the
figure and tighten it.
Pos: 23.13 /Serie 767 ( WAGO-SPEED WAY)/Anschluss D aten- und Versorgungskabel/I/O-M odule/Anschluss_S-BU S_4xM 12 - Bil d @ 5\mod_1249301323125_21.docx @ 40063 @ @ 1
Figure 15: S-BUS connected to a fieldbus coupler and modules
Pos: 23.14 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwechsel--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1
1
3